首页> 外文期刊>Electric Power Components and Systems >Induced Voltages on Pipelines Installed in Corridors of AC Power Lines
【24h】

Induced Voltages on Pipelines Installed in Corridors of AC Power Lines

机译:安装在交流电源线走廊中的管道上的感应电压

获取原文
获取原文并翻译 | 示例
           

摘要

An experimental reduced-scale rig was built to investigate the capacitive and inductive coupling caused by AC power transmission lines near unburied pipelines. A computer model for the experimental rig was created to investigate the different factors that may affect the coupling effect. The basic input data to the model consists of power line and pipeline geometrical configurations, conductor and pipeline physical characteristics including insulation and coating characteristics, and environmental parameters (such as soil characteristics, power source voltage, and equivalent source impedances). The model illustrates the effects of various parameters (length of parallelism, lateral distance, soil resistivity, current magnitude, and voltage magnitude) upon AC electromagnetic interference between transmission lines and nearby pipelines. The results of the computer model were verified experimentally. Good correlation between the experimental and software based simulated results is obtained, which validates the modeling approach of coupling between power transmission line and unburied pipeline.
机译:建造了一个试验性的小型钻机,以研究由未埋管道附近的交流输电线路引起的电容和电感耦合。创建了用于实验装置的计算机模型,以研究可能影响耦合效果的不同因素。该模型的基本输入数据包括电力线和管道的几何配置,导体和管道的物理特性(包括绝缘和涂层特性)以​​及环境参数(例如土壤特性,电源电压和等效电源阻抗)。该模型说明了各种参数(平行度,横向距离,土壤电阻率,电流幅值和电压幅值)对传输线和附近管道之间的交流电磁干扰的影响。实验结果验证了计算机模型的结果。实验结果与基于软件的仿真结果之间具有良好的相关性,验证了输电线路与未埋管道耦合的建模方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号