Multi-point grounding of the core is one of the common transformer faults. In this study, a homogenisation model based on the finite element method is developed for calculating multi-point grounding current of the transformer core. The equivalent conductivity in the direction normal to the laminations is determined by the analysis of fault current distribution and calculation of anisotropic resistances of the iron core, especially, considering the influence of insulation coating on the silicon steel sheet. The validity of the proposed model is verified by comparing the three-dimensional finite element simulation results with the experimental results. Finally, two typical faults are simulated to further study the characteristics of multi-point grounding current based on a distribution transformer, which may be useful for the optimisation of transformer core design.
机译:铁芯的多点接地是常见的变压器故障之一。在这项研究中,建立了基于有限元方法的均质化模型来计算变压器铁芯的多点接地电流。通过分析故障电流分布并计算铁芯的各向异性电阻,可以确定垂直于叠片方向的等效电导率,尤其要考虑绝缘涂层对硅钢板的影响。通过将三维有限元仿真结果与实验结果进行比较,验证了所提模型的有效性。最后,对两个典型故障进行了仿真,以进一步研究基于配电变压器的多点接地电流的特性,这可能对优化变压器铁心设计很有用。