Recently, the market for EVs (Electric vehicles) and HEVs (Hybrid electric vehicles) has been expanding. In these vehicles, rectangular wires have started to be used for the traction motor coil to increase the motor performance. As a result, the insulation techniques become important because the applied voltage between the wires is increasing due to a change in the motor structure and the increase in the driving voltage. In order to safeguard the motor insulation, partial discharge (PD) between coil wires must be controlled, and to do this, the coil wires should be coated with an insulator of a suitable thickness. For this purpose, the PD measurement technique is important in design and inspection on the manufacturing lines. However, the PD measurement between wires is unstable, and is especially affected by the measurement method and environmental factors. In this paper, we clarify the factors as well as the mechanism affecting the PD inception voltage (PDIV) between enameled rectangular wires under AC voltage. The effects of the ambient humidity, the pre-discharge conditions and the measuring frequency on the PDIV were analyzed. As a result, it was confirmed that when there was pre-discharge in a high humidity environment, the PDIV displayed fluctuating characteristics in which it momentarily decreased and then increased. We observed the discharges and analyzed the electric field distribution. The results showed that in high humidity environment, pre-discharge causes moisture contained in the air to adhere to the coating surfaces, resulting in an increase in the surface conductivity, which influences the electric field strength in the air gap between coil wires. These analyses indicated that the PDIV can be measured stably and reliably at high frequencies in a high humidity environment.
机译:近来,EV(电动车辆)和HEV(混合电动车辆)的市场正在扩大。在这些车辆中,已经开始将矩形线材用于牵引电动机线圈,以提高电动机性能。结果,绝缘技术变得重要,因为由于电动机结构的改变和驱动电压的增加,导线之间的施加电压增加。为了保护电动机的绝缘,必须控制线圈线之间的局部放电(PD),为此,应在线圈线上涂上合适厚度的绝缘体。为此,PD测量技术在生产线的设计和检查中很重要。然而,电线之间的局部放电测量是不稳定的,并且尤其受测量方法和环境因素的影响。在本文中,我们阐明了在交流电压下,漆包扁线之间的PD起始电压(PDIV)的影响因素以及影响机理。分析了环境湿度,预放电条件和测量频率对PDIV的影响。结果,证实了当在高湿度环境中进行预放电时,PDIV表现出波动特性,其瞬时降低然后增加。我们观察了放电并分析了电场分布。结果表明,在高湿度环境下,预放电会使空气中包含的水分粘附到涂层表面,从而导致表面电导率增加,从而影响线圈线之间气隙中的电场强度。这些分析表明,PDIV可以在高湿度环境中的高频下稳定可靠地进行测量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号