首页> 外文期刊>Thrombosis Journal >Successful retrieval of dislocated inferior vena cava filter using double vascular sheaths docking technology: case report
【24h】

Successful retrieval of dislocated inferior vena cava filter using double vascular sheaths docking technology: case report

机译:使用双血管护套对接技术成功检索位于脱位的下腔静脉滤网:案例报告

获取原文
           

摘要

Dislocation of inferior vena cava filter (IVCF) is a rare complication with potential IVC perforation and other life-threatening risks requiring early diagnosis and in-time retrieval. Most of dislocation IVCF in the past have been shelved or removed by open surgery. It is very difficult to retrieve the filters by interventional technology. Here we report a 49-year-old man suffering from dislocation of IVCF implanted due to deep vein thrombosis (DVT) in the right femoral vein. Successful retrieval of the IVCF using double sheaths docking technique was done soon after confirmation of the dislocation. Importance of monitoring and early detection of dislocation of IVCF should be emphasized to avoid further complications. The double vascular sheaths docking technique can be considered as a preferential option in difficult operative situation.
机译:下腔静脉过滤器(IVCF)的脱位是具有潜在的IVC穿孔和其他需要早期诊断和停止检索的危及生命的风险的罕见并发症。 过去的大部分脱位IVCF已经被开放手术搁置或除去。 通过介入技术检索过滤器是非常困难的。 在这里,我们报告了一名49岁的男子,由于右侧股骨静脉的深静脉血栓形成(DVT),植入了IVCF的脱位。 在确认脱位后,使用双护套对接技术成功检索IVCF使用双鞘对接技术。 应强调监测和早期检测IVCF错位的重要性,以避免进一步的并发症。 双血管护套对接技术可以被认为是难以操作情况的优先选择。