Cusp overlap technique for transcatheter self-expanding aortic valve implantation

机译:用于经导管自膨胀主动脉瓣植入的CUSP重叠技术

获取原文
           

摘要

Transcatheter aortic valve implantation (TAVI) may cause atrioventricular conduction disturbances and, consequently, the necessity for permanent pacemaker implantation (PPI). This is because the His bundle surfaces at the basal part of the membranous septum (in the neighbourhood of the non-coronary cusp) and implant depth greater than the length of the membranous septum may interfere with the conduction system [1]. To mitigate this risk, the valve should be implanted at a?high position to minimize the contact of the valve frame with the base of membranous septum. During TAVI, the valve is usually positioned in a?coplanar fluoroscopic projection with 3 cusps view, but for a?self-expanding valve, like the Evolut R (Medtronic, Minneapolis, Minnesota), such a?view does not ensure a?high implantation. However, a?recently proposed technique based on a?cusp overlap allows valve implantation at a?very high position and significantly reduces the risk of PPI [2, 3].
机译:经沟管主动脉瓣植入(Tavi)可能导致房室传导干扰,因此,永久起搏器植入(PPI)的必要性。 这是因为他的膜隔膜的基部的束表面(在非冠状动脉尖端的附近)和大于膜隔膜的长度的植入深度可能会干扰导电系统[1]。 为了减轻这种风险,应将阀门植入一个容量的阀门,以最小化阀架与膜隔膜的基部的接触。 在Tavi期间,阀门通常以3个尖头视图定位在一个荧光透视投影中,但是对于一个α自膨胀阀,如Evolut R(Medtronic,Minneapolis,Minnesota),这样的呢?观点不确保a 植入。 然而,a?最近提出的基于a的技术,尖锐的重叠允许阀门植入在一个非常高的位置并显着降低ppi的风险[2,3]。