摘要

In order to explore the law of smoke spread in the fire environment of an island-style subway station, this article takes an island-style subway as the research object. Based on the fire dynamics, pyrosim is used to establish a subway fire model to observe the smoke concentration and temperature changes under different fire locations. The study found that when the fire source is at the end of the platform layer, the flue gas concentration of the farthest evacuation channel and safety exit reaches 80% at 85s and 130s, respectively, and the flue gas temperature at the nearest exit and the farthest exit are at 32° and 28° respectively. When the fire source is in the middle of the platform layer, the smoke concentration of the evacuation channel and the safety exit reaches 80% at 70s and 105s respectively, and the temperature of the smoke at the exit exceeds 40°.
机译:为了探讨岛式地铁站火灾环境中的烟雾蔓延法,本文将岛式地铁作为研究对象。 基于消防动力学,Pyrosim用于建立地铁火模型,观察不同火灾位置下的烟雾浓度和温度变化。 研究发现,当火源在平台层的末端时,最远的抽空通道和安全出口的烟气浓度分别在85秒和130s处达到80%,最近的出口处的烟道气温度和烟道气温度 最远的出口分别为32°和28°。 当消防源处于平台层的中间时,抽空通道的烟雾浓度分别在70年代和105s处达到80%,并且出口处的烟雾的温度超过40°。