Background: High percentage of biomechanical complications such as screw loosening in dental implants can be related to implant–abutment (I/A) connection properties which affect the behavior of implant assembly against functional loads in the oral cavity. The aims of the present study were to compare the reverse torque values (RTVs) and failure loads of three abutment types with internal Morse taper connection. Materials and Methods: In this experimental in vitro study, eighteen implants (4.5 mm × 10 mm bone level implants, Implantium, Dentium Co, Seoul, South Korea) were divided into three groups with different abutments: two?piece (TP) abutment, one?piece (OP) abutment, and screw abutment (SA), mounted in stainless?steel blocks according to ISO 14801. After completion the torque/detorque protocol, a compressive load (1 mm/min) was applied at 30° off?axis until failure. Mean reverse torque/tightening torque (RT/TT) values and failure loads were analyzed with one?way ANOVA test and Tukey’s honest significant difference (α = 0.05). Failure modes were evaluated by radiography and stereomicroscopy. Results: RT/TT values in the TP group were lower than those in other groups (P 0.001). Highest failure loads were observed in SA group (P = 0.002). In radiographic evaluation, all specimens showed deformation in I/A interface. Conclusion: I/A connections with larger surface areas may lead to higher RTVs (e.g., OP and SA groups). Use of an additional screw and indexed area in TP group did not reduce the bending resistance under static loading.
机译:背景技术:牙科植入物中松动等螺杆松动的高百分比可以与植入邻接(I / A)连接性能有关,其影响植入物组件对口腔中的功能载荷的行为。本研究的目的是将三种邻接类型的反向扭矩值(RTV)和故障负载与内部摩尔斯锥形连接进行比较。材料和方法:在该实验中的体外研究中,十八植入物(4.5毫米×10mm的骨水平植入物,植物,初期,首尔,韩国)分为三组,具有不同的基台:两个?块(TP)邻接,一件(op)邻接和螺旋支座(SA),安装在不锈钢箱中,根据ISO 14801安装钢块。完成扭矩/排水量方案后,将压缩载荷(1mm / min)拍摄30°截止?轴直到失败。用一种方式分析平均反向扭矩/紧固扭矩(RT / TT)值和破坏载荷,并用一个方式分析ANOVA测试和Tukey的诚实显着差异(α= 0.05)。通过射线照相和立体镜检查评估失效模式。结果:TP组中的RT / TT值低于其他组(P <0.001)。在SA组中观察到最高的故障载荷(P = 0.002)。在射线照相评估中,所有标本在I / A界面中显示出变形。结论:与较大表面区域的连接可能导致更高的RTV(例如,OP和SA组)。在TP组中使用额外的螺杆和索引区域未降低静态负载下的弯曲电阻。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号