Investigation of tumor and vessel motion correlation in the liver

机译:肝脏肿瘤和血管运动相关性研究

获取原文
           

摘要

Intrafraction imaging‐based motion management systems for external beam radiotherapy can rely on internal surrogate structures when the target is not easily visualized. This work evaluated the validity of using liver vessels as internal surrogates for the estimation of liver tumor motion. Vessel and tumor motion were assessed using ten two‐dimensional sagittal MR cine datasets collected on the ViewRay MRIdian. For each case, a liver tumor and at least one vessel were tracked for 175?s. A tracking approach utilizing block matching and multiple simultaneous templates was applied. Accuracy of the tracked motion was calculated from the error between the tracked centroid position and manually defined ground truth annotations. The patient’s abdomen surface and diaphragm were manually annotated in all frames. The Pearson correlation coefficient (CC) was used to compare the motion of the features and tumor in the anterior–posterior (AP) and superior–inferior (SI) directions. The distance between the centroids of the features and the tumors was calculated to assess if feature proximity affects relative correlation, and the tumor range of motion was determined. Intra‐ and interfraction motion amplitude variabilities were evaluated to further assess the relationship between tumor and feature motion. The mean CC between the motion of the vessel and the tumor were 0.85?±?0.11 (AP) and 0.92?±?0.04 (SI), 0.83?±?0.11 (AP) and ?0.89?±?0.06 (SI) for the surface and tumor, and 0.80?±?0.17 (AP) and 0.94?±?0.03 (SI) for the diaphragm and tumor. For intrafraction analysis, the average amplitude variability was 2.47?±?0.77?mm (AP) and 3.14?±?1.49?mm (SI) for the vessels, 2.70?±?1.08?mm (AP) and 3.43?±?1.73?mm (SI) for the surface, and 2.76?±?1.41?mm (AP) and 2.91?±?1.38?mm (SI) for the diaphragm. No relationship between distance and motion correlation was observed. The motion of liver tumors and liver vessels was well correlated, making vessels a suitable surrogate for tumor motion in the liver.
机译:当目标不容易可视化时,用于外部光束放射治疗的基于内部射线放射的运动管理系统可以依赖于内部替代结构。这项工作评估了使用肝血管作为肝脏肿瘤运动估计的内替代的有效性。使用10二维矢状MR CINE数据集进行评估血管和肿瘤运动,在viewray MRIDIAN上收集。对于每种情况,跟踪肝脏肿瘤和至少一个容器175℃。应用了利用块匹配和多个同时模板的跟踪方法。从跟踪质心位置之间的误差计算跟踪运动的准确性,并手动定义了地面真相注释。在所有框架中手动注释患者的腹部表面和隔膜。 Pearson相关系数(CC)用于比较前后(AP)和优异的(Si)方向上的特征和肿瘤的运动。计算特征的质心与肿瘤之间的距离,以评估特征邻近是否影响相对相关性,并且确定运动的肿瘤范围。评估和交叉间运动幅度可变性以进一步评估肿瘤与特征运动之间的关系。血管运动和肿瘤之间的平均cc为0.85≤≤0.11(ap)和0.92?0.04(Si),0.83°?0.11(AP)和?0.89?±0.06(Si)表面和肿瘤,和0.80?±0.17(AP)和0.94?0.94?0.94?0.94?0.03(Si)用于隔膜和肿瘤。对于血管分析,平均幅度变异性为2.47?±0.77?mm(ap)和3.14?±1.49?mm(si),2.70?±1.08?mm(ap)和3.43?±1.73膜的毫米(Si),2.76?±1.41?mm(ap)和2.91?±1.38?mm(si)为隔膜。观察到距离和运动相关之间的关系。肝脏肿瘤和肝血管的运动良好相关,使血管在肝脏中肿瘤运动的合适替代物。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号