首页> 外文期刊>Orthopedic reviews. >Five-year prospective subsidence analysis of 100 cemented polished straight stems: A concise clinical and radiological follow-up observation
【24h】

Five-year prospective subsidence analysis of 100 cemented polished straight stems: A concise clinical and radiological follow-up observation

机译:五年前瞻性沉降分析100个粘贴抛光直茎:简明临床和放射性后续观察

获取原文
           

摘要

Early subsidence (1.5mm) has been shown to be an indicator for later aseptic loosening of cemented hip stems. For the cemented twinSys? stem we published excellent short-term results at 2 years. Midterm data for this stem are available from national registers (NZL, NL), however in all of these sources, clinical and radiological results are missing. Aim of our study was to analyse mid-term survival and radiological changes around the cemented twinSys?stem with special emphasis on subsidence using EBRA-FCA. We conducted a prospective clinical and radiological 5-year follow-up study of 100 consecutive hybrid total hip arthroplasties (THA) using a polished, cemented collarless straight stem (twinSys?, Mathys AG?Bettlach, Switzerland) with a cementless monobloc pressfit cup (RM pressfit?, Mathys AG? Bettlach, Switzerland). Median age at surgery was 79 (69 to 93) years. No patient was lost to follow-up. Survival rates were calculated using the Kaplan-Meier method. Clinical (Harris Hip Score [HHS]) and radiological (cementing quality, alignment, osteolysis, debonding and cortical atrophy) outcomes and an in-depth subsidence analysis using EBRA-FCA were performed. 22 patients died in the course of follow-up unrelated to surgery, 21 stems had an incomplete radiological follow-up. 2 stems were revised, both due to an infection. The survival rate for the stem at 5 years was 98.0% (95% CI 95.3-100%). The survival rate of the stem for revision due to aseptic loosening at 5 years was 100%. The HHS improved from 53 (14-86) points preoperatively to 90 (49-100) points 5 years after surgery. Osteolysis was found in 2 stems without clinical symptoms. In 49 out of 55 patients with a complete radiological follow-up, the EBRA-FCA analysis was possible and showed an average subsidence of 0.66 (95% CI 0.46 to 0.86) mm 5 years after surgery. 10 patients showed a subsidence 1 mm, 5 of which bigger than 1.5 mm. Subsidence was independent from radiological changes and cementing quality. The cemented twinSys? stem showed excellent clinical and radiological mid-term results at five years’ follow-up and seems to be a reliable implant.
机译:早期沉降(> 1.5mm)已被证明是后来无菌松动的胶结髋茎的指标。对于泥土的孪生?茎我们在2年时发表了出色的短期结果。该茎中的中期数据可从国家寄存器(NZL,NL)获得,但在所有这些来源中,缺少临床和放射性结果。我们的研究目的是分析巩固的孪生周围的中期存活和放射性变化?源于使用EBRA-FCA的特别强调沉降。我们使用抛光的粘合的无链条直茎(Tha)进行了100个连续的杂交总髋关节关节塑料(THA)的前瞻性临床和放射性5年的随访研究,用粘稠的粘合的无链条直茎(Twinsys?,Mathys Ag?Bettlach,瑞士),用粘稠的单对流净流量杯( RM PressFit ?,Mathys AG?Bettlach,瑞士)。手术中位年龄为79(69至93岁)。没有病人失去了随访。使用Kaplan-Meier方法计算存活率。临床(哈里斯臀部评分[HHS])和放射性(固井质量,取向,骨溶解,剥离和皮质萎缩)结果以及使用EBRA-FCA的深入沉降分析。 22例患者在随访与手术无关的过程中,21个茎有一个不完全的放射性随访。由于感染而修改了2个茎。 5年5岁的茎的存活率为98.0%(95%CI 95.3-100%)。 5年内无菌松动导致茎干的存活率为100%。 HHS在手术后5年50(49-100)分,从53(14-86)点改善。在没有临床症状的情况下,在2个茎中发现了骨解。在55例患者中有49名患者中有完整放射随访中,eBRA-FCA分析是可能的,并且在手术后5年5年内显示平均沉降0.66(95%CI 0.46至0.86)。 10名患者显示沉降> 1毫米,其中5个大于1.5毫米。沉降是独立的放射性变化和巩固质量。水泥的孪生?茎显示出优异的临床和放射学中期的结果,在五年后的随访中,似乎是可靠的植入物。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号