首页> 外文期刊>Materials >Degradation of Axial Ultimate Load-Bearing Capacity of Circular Thin-Walled Concrete-Filled Steel Tubular Stub Columns after Corrosion
【24h】

Degradation of Axial Ultimate Load-Bearing Capacity of Circular Thin-Walled Concrete-Filled Steel Tubular Stub Columns after Corrosion

机译:腐蚀后圆形薄壁混凝土钢管柱轴承轴承轴承承载能力的劣化

获取原文
           

摘要

This work aimed to investigate the effects of steel tube corrosion on the axial ultimate load-bearing capacity (AULC) of circular thin-walled concrete-filled steel tubular (CFST) members. Circular thin-walled CFST stub column specimens were made of steel tubes with various wall-thicknesses. These CFST column specimens were subjected to an accelerated corrosion test, where the steel tubes were corroded to different degrees of corrosion. Then, these CFST specimens with corroded steel tubes experienced an axial static loading test. Results show that the failure patterns of circular thin-walled CFST stub columns with corroded steel tubes are different from those of the counterpart CFST columns with ordinary wall-thickness steel tubes, which is a typical failure mode of shear bulging with slight local outward buckling. The ultimate strength and plastic deformation capacity of the CFST specimens decreased with the increasing degree of steel corrosion. The failure modes of the specimens still belonged to ductile failure because of the confinement of outer steel tube. The degree of steel tube corrosion, diameter-to-thickness ratio, and confinement coefficient had substantial influences on the AULC and the ultimate compressive strength of circular thin-walled CFST stub columns. A simple AULC prediction model for corroded circular thin-walled CFST stub columns was presented through the regression of the experimental data and parameter analysis.
机译:这项工作旨在探讨钢管腐蚀对圆形宽壁混凝土钢管(CFST)构件的轴向终极承载能力(梨子)的影响。圆形薄壁CFST短柱标本由具有各种壁厚的钢管制成。对这些CFST柱试样进行加速腐蚀试验,其中钢管腐蚀到不同程度的腐蚀。然后,具有腐蚀钢管的这些CFST样本经历了轴向静态负载试验。结果表明,具有腐蚀钢管的圆形薄壁CFST短柱柱的故障模式与具有普通壁厚钢管的对应CFST柱的故障模式,这是具有轻微局部向外屈曲的剪切凸出的典型故障模式。 CFST标本的极限强度和塑性变形能力随着钢腐蚀程度的增加而降低。由于外钢管的限制,标本的失效模式仍然属于韧性故障。钢管腐蚀,直径到厚度比和限制系数对紫色薄壁CFST短柱的极限压缩强度有很大的影响。通过对实验数据的回归给出了一种用于腐蚀圆形薄壁CFST短柱柱的简单抗振预测模型。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号