首页> 外文期刊>Global Pediatric Health >User-Informed Medical Device Development: A Case Study for Pediatric Malnutrition Assessment
【24h】

User-Informed Medical Device Development: A Case Study for Pediatric Malnutrition Assessment

机译:用户知识的医疗设备开发:儿科营养不良评估案例研究

获取原文
           

摘要

Background. Mid-upper arm circumference (MUAC) has been extensively used to classify pediatric malnutrition. Recently, MUAC z score was recommended; however, the logistics of implementation were not addressed. This study examines the usability of a device that provides MUAC and corresponding z score range in a single device. Methods. This was a single-center study of nutrition services providers. The device was applied to children aged 2 months to 18 years admitted as inpatients or seen as outpatients. Surveys incorporated benchmarking questions, assessed the ease with which respondents could perform 6 critical tasks, and provided an open-ended question to elicit feedback. Users were surveyed monthly until saturation was reached. Survey data were analyzed in aggregate and cross-tabulated by the respondents’ experience with the device. Thematic analysis of the open-ended responses followed a structured approach. Results. Sixty device users responded to the survey 280 times. Respondents were female (100%) with a mean age of 45.2 ± 13.2 years and 9.6 ± 8.0 years in practice. Increasing device use was accompanied by significantly shortened measuring times (P .001) and shifts in ease of performance for 5 of 6 critical tasks (P .05). Open-ended response themes related largely to design and materials. These were used to iteratively refine the device. Conclusions. The active engagement of end users in the real-world testing of our nutritional assessment device allowed us to refine the innovation with special attention paid to the needs of dietitians. The result is a device the majority of dietitians found easy to use, efficient, convenient, and preferable to alternative measurement options.
机译:背景。中上部臂周长(MUAC)已被广泛用于分类小儿营养不良。最近,建议使用muac z得分;但是,未解决实施的物流。本研究介绍了在单个设备中提供MUAC和相应Z得分范围的设备的可用性。方法。这是对营养服务提供商的单一中心研究。将该装置适用于2个月至18岁的儿童作为住院患者入境或被视为门诊病人。调查纳入基准问题,评估了受访者可以执行6个关键任务的缓解,并提供了一个引出反馈的开放式问题。用户每月调查,直到达到饱和度。调查数据分析了聚集并通过受访者对设备的经验交叉制成。对开放式响应的主题分析遵循结构化方法。结果。六十台设备用户响应调查280次。受访者是女性(100%),平均年龄为45.2±13.2岁,练习9.6±8.0岁。随着测量时间的速度显着缩短了(P <.001),伴随着5个关键任务中的5个(P <.05),增加了设备使用。开放式响应主题主要与设计和材料有关。这些用于迭代地改进装置。结论。最终用户在营养评估装置的真实测试中的积极参与使我们能够特别注意营养人员的需要。结果是一款大多数营养师发现易于使用,高效,方便,优选替代测量选项的设备。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号