A simple angle-measuring instrument for measuring cemented stem anteversion during total hip arthroplasty

机译:一种简单的角度测量仪,用于在总髋关节置换术期间测量粘液茎抗变性

获取原文
           

摘要

BACKGROUND:During total hip arthroplasty (THA), the accurate placement of the femoral components is an important determinant of the success of the procedure. This study assessed the accuracy of cemented stem placement using a new angle-measuring instrument. The primary objective was to investigate the accuracy of the intraoperative measurements of cemented stem anteversion obtained using the angle-measuring instrument. Our secondary objective was to evaluate the accuracy of stem positioning performed using the angle-measuring instrument.METHODS:We compared the intraoperative stem anteversion measurements obtained using the angle-measuring instrument with postoperative stem anteversion measurements obtained using computed tomography in 149 hips (measurement accuracy). We also compared the target angle and postoperative stem anteversion in 105 hips (implantation accuracy).RESULTS:The mean amount of intraoperative stem anteversion was 37.9°?±?10.1°, and the mean amount of postoperative stem anteversion was 37.0°?±?10.4°. The mean measurement accuracy was 0.9°?±?6.1°, and the absolute measurement accuracy was 4.9°?±?3.7°. The correlation coefficient for the relationship between the intraoperative and postoperative stem anteversion measurements was 0.824 (p?=?0.000). The mean amount of target angle was 37.4°?±?7.6°, and the mean amount of postoperative stem anteversion was 35.9°?±?9.1°. The mean implantation accuracy was 1.4°?±?5.6°, and the mean absolute implantation accuracy was 4.3°?±?3.6°. The correlation coefficient for the relationship between the target angle and postoperative stem anteversion was 0.795 (p?=?0.000).CONCLUSIONS:The angle-measuring instrument measured intraoperative stem anteversion accurately, and cemented stem was implanted accurately during THA with the angle-measuring instrument.
机译:背景:在总髋关节置换术(THA)期间,股骨成分的准确放置是程序成功的重要决定因素。该研究评估了使用新的角度测量仪器的胶合杆放置的精度。主要目的是研究使用角度测量仪器获得的粘液茎干反液的术中测量的准确性。我们的二级目标是评估使用角度测量仪器进行的阀杆定位的准确性。方法:比较了使用149个臀部的计算机断层扫描获得的角度测量仪器获得的术中茎扰测量测量,从149髋(测量精度测量精度)。我们还将目标角度和术后茎抗逆转率与105髋(植入精度)进行比较。结果:术中茎逆转率的平均量为37.9°→10.1°,术后茎逆转的平均量为37.0°? 10.4°。平均测量精度为0.9°?±6.1°,绝对测量精度为4.9°?±3.7°。术中和术后茎腹部反转测量的关系的相关系数为0.824(p?= 0.000)。靶角的平均量为37.4°?±7.6°,术后茎逆转率的平均量为35.9°?±9.1°。平均植入精度为1.4°?±5.6°,平均绝对植入精度为4.3°±3.6°。靶角度和术后茎逆转率之间关系的相关系数为0.795(p?= 0.000)。结论:角度测量仪器精确测量术中茎腹部,并且在角度测量期间精确地植入胶结杆乐器。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号