Examination of inter-rater and intra-rater reliability during retentive force measurement of different clasps using the developed small-sized retentive force measurement device

机译:使用开发的小尺寸保持力测量装置检查不同扣除的帧间帧间帧内帧内速率可靠性

获取原文
   

获取外文期刊封面封底 >>

       

摘要

The design process of a removable partial denture (RPD) consists of rests, major connectors, minor connectors, denture base, and retainer. The abutment tooth contour determines the location of the retention portion of the clasp at the retention areas. The load capacity of the clasp depends on various factors such as type, the position of a clasp, tooth position, clasp length, and pullout location. As a general rule, the amount of retention required to dislodge the RPD from the supporting structure should always be the minimum necessary to resist reasonable dislodging forces. Excessive force from the clasps may cause many problems. Although there are many reports on the retentive force of cast clasps using large devices, it has not been possible to measure it using simple devices until now. The purpose of the present study is to develop a small-sized retentive force measurement device that can easily measure the retentive force of a clasp used for an RPD. It is to examine inter-rater and intra-rater reliability. A small-sized retentive force measurement device that can be easily measured in the laboratory has been developed. Using commercially available hard plaster cast, a skilled dental technician has made 10 types of cast clasps used in clinical practice using conventional techniques. Three assessors measured the retentive force of 10 types of cast clasps. To confirm the reliability, the intra-class correlation coefficients ICC (1,1) and ICC (1,3) of the 3 assessors were calculated, and the reliability within the assessor was examined. The inter-class correlation coefficients ICC (3,1) and ICC (3,3) were calculated, and the reliability of the assessors was examined. The intra-class correlation coefficients of 3 assessors are as follows: assessor 1 has ICC (1,1)?=?0.971, ICC (1,3)?=?0.990, assessor 2 has ICC (1,1)?=?0.967, ICC (1,3)?=?0.989, assessor 3 has ICC (1,1)?=?0.962, ICC (1,3)?=?0.987. The inter-class correlation coefficients of 3 assessors are as follows: ICC (3,1)?=?0.993, ICC (3,3)?=?0.998. From the evaluation standard of the intraclass correlation coefficients of reliability value by ICC, it was evaluated as almost perfect and high reproducibility was confirmed. The developed small-sized retentive force measurement device has reproducibility within and between the assessors.
机译:可拆卸部分义齿(RPD)的设计过程包括休息,主要连接器,小连接器,义齿基座和保持器。邻接齿轮廓确定保持区域处扣环的保持部分的位置。扣环的负载能力取决于各种因素,例如类型,扣环,齿位置,扣环长度和拉出位置的各种因素。作为一般规则,向支持结构移位RPD所需的保留量应始终是抵抗合理移位力所必需的最低限度。来自扣子的过度力可能导致许多问题。虽然使用大型器件有很多关于铸造扣式铸造的铸件的报告,但仍然无法使用简单的设备来测量它。本研究的目的是开发一种小尺寸的保留力测量装置,可以容易地测量用于RPD的扣的保持力。它是检查帧间间和帧内的可靠性。已经开发了一种在实验室中可以容易地测量的小尺寸的保持力测量装置。使用市售的硬质膏铸造,熟练的牙科技师已经使用常规技术在临床实践中使用了10种类型的铸件扣。三个评估员测量了10种类型的铸扣的保持力。为了确认可靠性,计算了3个评估仪的类内相关系数ICC(1,1)和ICC(1,3),检查了评估员的可靠性。计算了类间相关系数ICC(3,1)和ICC(3,3),检查了评估员的可靠性。 3评估员的类内相关系数如下:评估仪1具有ICC(1,1)?=?0.971,ICC(1,3)?=?0.990,评估员2具有ICC(1,1)?=? 0.967,ICC(1,3)?=?0.989,评估仪3具有ICC(1,1)?=?0.962,ICC(1,3)?= 0.987。 3评估员的阶级相关系数如下:ICC(3,1)?=?0.993,ICC(3,3)?=?0.998。从ICC的可靠性值的腹积相关系数的评估标准,评估为几乎完美,并且确认了高再现性。开发的小型保留力测量装置具有评估员内部和之间的再现性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号