Of 337 urine specimens evaluated, 75 of the 113 that showed positive readings on the Bac-T-Screen urine-screening instrument were found by subsequent semiquantitative culture to yield either less than 10,000 CFU of mixed bacteria per ml or no growth (less than 100 CFU/ml by our criteria). We tried to determine what factors contributed to the positive Bac-T-Screen results by examining the 75 Bac-T-Screen-positive urine specimens with three visual methods: Gram staining, hemacytometer chamber counting, and filtering through a 5.0-microns-pore-size nitrocellulose filter with subsequent microscopic examination of the stained filter. Somatic cells and other particles present in those urine specimens that yielded positive readings by the Bac-T-Screen included epithelial cells in 43%, crystals and amorphous material in 33%, and leukocytes in 17% of the specimens. There was no relationship between the numbers of particles seen in urine and the magnitude of the relative absorbance reading obtained with the Bac-T-Screen. A retrospective chart review was conducted for patients with positive Bac-T-Screen results and negative cultures. Of the 75 patients, 6 were thought to have urinary tract infections on the basis of clinical criteria; the majority of the remaining 69 patients had clinical histories revealing systemic or urogenital conditions consistent with shedding of particles in the urine. A positive reading by the Bac-T-Screen system seemed to be related to the presence of somatic cells and other particles in urine; bacteriuria was not always detectable in these cases.
机译:在评估的337个尿液样本中,通过随后的半定量培养发现,在Bac-T-Screen尿液筛检仪器上显示阳性读数的113个尿液样本中,每毫升产生的混合细菌少于10,000 CFU或无生长(少于100 CFU / ml(根据我们的标准)。我们试图通过三种视觉方法检查75个Bac-T-Screen阳性尿液样本,以确定哪些因素有助于Bac-T-Screen阳性结果:革兰染色,血细胞计数器计数以及通过5.0微米孔的过滤尺寸的硝酸纤维素滤膜,然后对染色的滤膜进行显微镜检查。通过Bac-T-Screen获得阳性读数的尿液样本中存在体细胞和其他颗粒,其中上皮细胞占43%,晶体和无定形物质占33%,白细胞占17%。在尿液中看到的颗粒数量与使用Bac-T-Screen筛查仪获得的相对吸光度读数的大小之间没有关系。对Bac-T-Screen结果阳性和培养阴性的患者进行回顾性图表审查。根据临床标准,在75名患者中,有6名被认为患有尿路感染。其余69位患者中的大多数都有临床病史,显示全身或泌尿生殖系统疾病与尿液中的颗粒脱落相一致。 Bac-T-Screen系统的阳性读数似乎与尿液中存在体细胞和其他颗粒有关。在这些情况下,并非总是可以检测到细菌尿。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号