Research on Optimal Inspection Strategy for Overhead Transmission Line Based on Smart Grid

机译:基于智能电网的架空输电线路优化检查策略研究

获取原文
           

摘要

Due to the urgent demand for the monitoring of overhead transmission lines in smart grid, this paper proposes an optimal inspection strategy for overhead transmission line considering time-varying failure rate. Based on the goal benefit function of inspection cost, failure electric cost and the maintaining reliability cost, modal of the inspection strategy is established with genetic algorithm. The reliability index could contribute to a dynamic and variable inspection cycle of transmission line via genetic algorithm. According to the calculation results of the middle area of China, it is presented that the algorithm can work out inspection strategy according to the actual failure rate, and get a rational and economical, regional, seasonal, dynamic inspection cycle plan. Thus, it can avoid the traditional over-inspection and lack-inspection problems. The state of transmission line can be guaranteed in more economical way, satisfying the demand of real-time capability and reliability.
机译:针对智能电网中架空输电线路监测的迫切需求,提出一种考虑时变故障率的架空输电线路最优检测策略。基于检验成本,故障用电成本和维护可靠性成本的目标收益函数,利用遗传算法建立了检验策略的模型。可靠性指标可以通过遗传算法促进输电线路的动态和可变检查周期。根据我国中部地区的计算结果,提出该算法可以根据实际的故障率制定检查策略,并得到合理,经济,区域,季节,动态的检查周期计划。因此,它可以避免传统的过度检查和缺乏检查的问题。可以更经济地保证传输线的状态,满足实时能力和可靠性的要求。