摘要

The article presents a method for selecting the parameters of the current-voltage characteristics of adjustable reactive power compensation devices used at sectioning stations of railway sections electrified by alternating current with a voltage of 27.5 kV. This technique is based on the experience of operating two types of devices in the traction power supply system. Power control of these devices is implemented by the voltage level at the switching point. Selection of the setpoint voltage and slope characteristics was done. The developed method allows increasing the efficiency of devices by eliminating the voltage losses on the active component of traction loads. That will reduce the loss of electricity in the system of traction power supply. Changing the parameters of the characteristics will increase the relationship between the reactive power consumed in the zone and the voltage measured by the devices. Following the results of the formation of the methodology, an example of the choice of characteristics for a real compensation device is presented.
机译:本文提出了一种方法,用于选择在交流电压为27.5 kV的电气化铁路段的分段站使用的可调无功功率补偿装置的电流-电压特性的参数。该技术基于操作牵引电源系统中两种类型的设备的经验。这些设备的功率控制通过开关点的电压电平来实现。选择设定电压和斜率特性。所开发的方法通过消除牵引负载有源组件上的电压损耗来提高设备效率。这将减少牵引电源系统中的电力损耗。更改特性参数将增加区域中消耗的无功功率与设备测量的电压之间的关系。遵循方法论的形成结果,给出了用于实际补偿装置的特性选择的示例。