首页> 外文期刊>International Journal of Engineering Research and Applications >Total Harmonic Distortion Analysis of Three Phase Nonlinear Load Using H-Bridge Vsi Topology Based_ Dstatcom
【24h】

Total Harmonic Distortion Analysis of Three Phase Nonlinear Load Using H-Bridge Vsi Topology Based_ Dstatcom

机译:基于H桥Vsi拓扑的三相非线性负载总谐波失真分析_ Dstatcom

获取原文
           

摘要

This paper presents the detailed model, control and simulation of H-Bridge VSI topology based DSTATCOM. It also describes the control of multilevel inverter supplied by Photovoltaic system and a battery bank which is connected to the supply system. It is well known that the Power Quality of the Multililevel Inverter signals depends upon the number of levels. Basic structure and operating principle of the Cascaded H-Bridge Multilevel Inverter are explored. The phase shifted SPWM is used for reducing the lower order harmonics of the output voltage and the Park's transformation is employed to decouple the active and reactive power components for regulating the compensation power. The controller equations are such that the phase shifted SPWM pulses are generated automatically for any number of levels. The effectiveness of the proposal method is evaluated in simulation by using Matlab/Simulink. The results of the simulation are analyzed and discussed.
机译:本文介绍了基于DSTATCOM的H桥VSI拓扑的详细模型,控制和仿真。它还描述了由光伏系统提供的多电平逆变器的控制以及与供电系统相连的电池组。众所周知,多电平逆变器信号的电能质量取决于电平的数量。探讨了级联H桥多电平逆变器的基本结构和工作原理。相移SPWM用于降低输出电压的低次谐波,而Park变换用于解耦有功和无功功率分量,以调节补偿功率。控制器方程式使得可以针对任意数量的电平自动生成相移SPWM脉冲。使用Matlab / Simulink在仿真中评估了该建议方法的有效性。对仿真结果进行了分析和讨论。