...
首页> 外文期刊>Journal of Veterinary Internal Medicine >Clinical utility of urine specific gravity, electrical conductivity, and color as on‐farm methods for evaluating urine concentration in dairy cattle
【24h】

Clinical utility of urine specific gravity, electrical conductivity, and color as on‐farm methods for evaluating urine concentration in dairy cattle

机译:尿比重,电导率和颜色作为评估奶牛尿液浓度的农场方法的临床应用

获取原文
           

摘要

Background Urine concentration (UC) provides clinically useful information concerning hydration status and renal function of animals. Objectives To characterize the clinical performance of urine specific gravity measured by optical refractometry (U SG‐R ) or Multistix‐SG urine reagent dipstick (U SG‐D ), urine electrical conductivity using an OAKTON Con 6 conductivity handheld meter (U EC ), urine color (U Color ) using a custom‐designed 8‐point color chart, and urine creatinine concentration (U Creat ) for assessing UC in dairy cattle. Animals 20 periparturient Holstein‐Friesian cows. Methods Urine was obtained by perineal stimulation or urethral catheterization and urine osmolality (U Osm , reference method), U SG‐R , U SG‐D , U EC , U Color , and U Creat determined. Diagnostic test performance was evaluated using Spearman's rho and logistic regression to determine the area under the receiver operating curve (AUC) and optimal cut point for diagnosing hypohydration (U Osm ≥800?mOsm/kg). P ??.05 was considered significant. Results The best performing test for diagnosing hypohydration was U SG‐R (AUC?=?0.90) at an optimal cut point ≥1.030. The second‐best performing test was U EC (AUC?=?0.82) at a cut point of ≥23.7 mS/cm, followed by U Creat (AUC?=?0.76) at a cut point of ≥95.3 mg/dL, and U Color (AUC?=?0.74) at a cut point of ≥4 on an 8‐point scale. Urine specific gravity measured by dipstick performed poorly (AUC?=?0.63). Conclusions and Clinical Importance U SG‐R and U EC provide practical and sufficiently accurate methods for measuring UC in dairy cattle. Urine color had moderate clinical utility as a no‐cost cow‐side method for assessing UC, whereas dipstick refractometry is not recommended for assessing UC.
机译:背景尿液浓度(UC)提供了有关动物的水合状态和肾功能的临床有用信息。目的通过光学折光仪(U SG‐R)或Multistix‐SG尿液试剂量尺(U SG‐D),OAKTON Con 6电导率手持测量仪(U EC)来表征尿液比重的临床表现,使用定制设计的8点色表绘制尿液颜色(U Color),并使用尿肌酐浓度(U Creat)评估奶牛的UC。动物20例围产期荷斯坦奶牛。方法通过会阴刺激或尿道插管获得尿液,并用尿渗透压(U Osm,参考方法),U SG-R,U SG-D,U EC,U Color和U Creat进行测定。使用Spearman的rho和logistic回归评估诊断测试的性能,以确定接收器工作曲线(AUC)下的面积和诊断低水化的最佳切点(U Osm≥800?mOsm / kg)。 P≤0.05。结果在最佳切点≥1.030时,诊断水合作用的最佳性能测试是U SG‐R(AUC?=?0.90)。表现第二好的测试是在切割点≥23.7 mS / cm的U EC(AUC?=?0.82),然后在切割点≥95.3mg / dL的是U Creat(AUC?=?0.76),以及U色彩(AUC?=?0.74),在8点标度上的切点≥4。用量油尺测得的尿比重性能较差(AUC≥0.63)。结论和临床重要性U SG‐R和U EC为测量奶牛的UC提供了实用且足够准确的方法。尿液颜色作为评估UC的免费的牛侧方法具有中等的临床效用,但是不建议使用试纸验光仪来评估UC。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号