Background:Red blood cell (RBC) analysis is a key feature in the evaluation of hematological disorders. The gold standard light microscopy technique has high sensitivity, but is a relativity time-consuming and labor intensive procedure. This study tested the sensitivity and specificity of gold standard light microscopy manual differential to the CellaVision? DM96 (CCS; CellaVision, Lund, Sweden) automated image analysis system, which takes digital images of samples at high magnification and compares these images with an artificial neural network based on a database of cells and preclassified according to RBC morphology.Methods:In this study, 212 abnormal peripheral blood smears within the Calgary Laboratory Services network of hospital laboratories were selected and assessed for 15 different RBC morphologic abnormalities by manual microscopy. The same samples were reassessed as a manual addition from the instrument screen using the CellaVision? DM96 system with 8 microscope high power fields (×100 objective and a 22 mm ocular). The results of the investigation were then used to calculate the sensitivity and specificity of the CellaVision? DM96 system in reference to light microscopy.Results:The sensitivity ranged from a low of 33% (RBC agglutination) to a high of 100% (sickle cells, stomatocytes). The remainder of the RBC abnormalities tested somewhere between these two extremes. The specificity ranged from 84% (schistocytes) to 99.5% (sickle cells, stomatocytes).Conclusions:Our results showed generally high specificities but variable sensitivities for RBC morphologic abnormalities.
机译:背景:红细胞(RBC)分析是血液学疾病评估的关键特征。金标准的光学显微镜技术具有很高的灵敏度,但是相对而言既费时又费力。这项研究测试了金标准光学显微镜手动差异法对CellaVision?的敏感性和特异性。 DM96(CCS; CellaVision,Lund,Sweden)自动化图像分析系统,该系统以高倍率拍摄样品的数字图像,并将这些图像与基于细胞数据库并根据RBC形态预先分类的人工神经网络进行比较。这项研究从医院实验室的卡尔加里实验室服务网络中选择了212个外周血涂片异常,并通过手动显微镜对15种不同的RBC形态异常进行了评估。使用CellaVision?从仪器屏幕上重新评估相同的样品作为手动添加。 DM96系统具有8个显微镜高倍视野(×100物镜和22毫米目镜)。然后将调查结果用于计算CellaVision?的敏感性和特异性。 DM96系统在光学显微镜方面的作用。结果:灵敏度范围从低至33%(RBC凝集)到高至100%(镰状细胞,口腔细胞)。在这两个极端之间的某个地方测试了其余的RBC异常。特异性范围从84%(血吸细胞)到99.5%(镰状细胞,口腔细胞)。结论:我们的结果显示,通常具有较高的特异性,但对RBC形态异常的敏感性各不相同。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号