首页> 外文期刊>Journal of Pathology Informatics >Comparative study between quantitative digital image analysis and fluorescence in situ hybridization of breast cancer equivocal human epidermal growth factor receptors 2 score 2+ cases
【24h】

Comparative study between quantitative digital image analysis and fluorescence in situ hybridization of breast cancer equivocal human epidermal growth factor receptors 2 score 2+ cases

机译:乳腺癌等位人类表皮生长因子受体2评分2+病例定量数字图像分析与荧光原位杂交的比较研究

获取原文
           

摘要

Background:Optimization of workflow for breast cancer samples with equivocal human epidermal growth factor receptors 2 (HER2)eu score 2+ results in routine practice, remains to be a central focus of the on-going efforts to assess HER2 status. According to the College of American Pathologists/American Society of Clinical Oncology guidelines equivocal HER2eu score 2+ cases are subject for further testing, usually by fluorescence in situ hybridization (FISH) investigations. It still remains on open question, whether quantitative digital image analysis of HER2 immunohistochemistry (IHC) stained slides can assist in further refining the HER2 score 2+.Aim of this Work:To assess utility of quantitative digital analysis of IHC stained slides and compare its performance to FISH in cases of breast cancer with equivocal HER2 score 2+.Materials and Methods:Fifteen specimens (previously diagnosed as breast cancer and was evaluated as HER 2- score 2+) represented the study population. Contemporary new cuts were prepared for re-evaluation of HER2 immunohistochemical studies and FISH examination. All the cases were digitally scanned by iScan (Produced by BioImagene [Now Roche-Ventana]). The IHC signals of HER2 were measured using an automated image analyzing system (MECES, www.Diagnomx.eu/meces). Finally, a comparative study was done between the results of the FISH and the quantitative analysis of the virtual slides.Results:Three out of the 15 cases with equivocal HER2 score 2+, turned out to be positive (3+) by quantitative digital analysis, and 12 were found to be negative in FISH too. Two of these three positive cases proved to be positive with FISH, and only one was negative.Conclusions:Quantitative digital analysis is highly sensitive and relatively specific when compared to FISH in detecting HER2eu overexpression. Therefore, it represents a potential reliable substitute for FISH in breast cancer cases, which desire further refinement of equivocal IHC results.
机译:背景:对人类表皮生长因子受体2(HER2)/ neu评分2+含糊不清的乳腺癌样品的工作流程的优化在常规实践中仍然是不断评估HER2状态的重点。根据美国病理学家学院/美国临床肿瘤学会指南,通常通过荧光原位杂交(FISH)研究对HER2 / neu得分2+以上的病例进行进一步测试。 HER2免疫组化(IHC)染色载玻片的定量数字图像分析是否可以帮助进一步完善HER2评分2+仍是一个尚待解决的问题。这项工作的目的:评估IHC染色载玻片的定量数字分析的实用性并对其进行比较HER2得分≥2的乳腺癌患者对FISH的表现。材料和方法:15份标本(先前诊断为乳腺癌,评估为HER 2得分2+)代表研究人群。为重新评估HER2免疫组织化学研究和FISH检查准备了当代的新方法。所有病例均通过iScan(由BioImagene [Now Roche-Ventana]生产)进行数字扫描。使用自动图像分析系统(MECES,www.Diagnomx.eu / meces)测量HER2的IHC信号。最后,在FISH结果与虚拟载玻片的定量分析之间进行了比较研究。结果:HER2模棱两可的15例中有3例,通过定量数字分析结果为阳性(3+) ,还有12个在FISH中也呈阴性。这三例阳性病例中有2例经FISH证实为阳性,而只有1例为阴性。结论:与FISH相比,定量数字分析在检测HER2 / neu过表达方面具有很高的敏感性和特异性。因此,它代表了在乳腺癌病例中可能需要的可靠的FISH替代品,希望进一步完善模棱两可的IHC结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号