首页> 外文期刊>Journal of Physics: Conference Series >Macrobending Loss Measurements of G.657 Fiber with Suppression of Ripple Effect Induced by Whispering Gallery Modes
【24h】

Macrobending Loss Measurements of G.657 Fiber with Suppression of Ripple Effect Induced by Whispering Gallery Modes

机译:G.657光纤的宏弯损耗测量,同时抑制耳语画廊模式引起的纹波效应

获取原文
           

摘要

Abstract During the macrobending loss performance tests of ITU-T G.657 fiber under small bending radius, the test results show big differencesin many tests for the same test samples and conditions. Research shows that the main reason for the difference is Whispering gallery modes phenomenon in small bending radius [1]. The inappropriate test conditions can affect the accuracy of macrobending loss test results. In the test of product validation and field application, single wavelength light sourc.
机译:摘要在小弯曲半径条件下对ITU-T G.657光纤进行宏弯曲损耗性能测试时,在相同测试样品和相同条件下的许多测试中,测试结果显示出很大差异。研究表明,造成这种差异的主要原因是小弯曲半径下的“回音壁模式”现象[1]。不适当的测试条件可能会影响宏弯损耗测试结果的准确性。在产品验证和现场应用的测试中,单波长光源。