首页> 外文期刊>Journal of Personalized Medicine >Accuracy in Wrist-Worn, Sensor-Based Measurements of Heart Rate and Energy Expenditure in a Diverse Cohort
【24h】

Accuracy in Wrist-Worn, Sensor-Based Measurements of Heart Rate and Energy Expenditure in a Diverse Cohort

机译:基于手腕的,基于传感器的不同人群心率和能量消耗测量的准确性

获取原文
           

摘要

The ability to measure physical activity through wrist-worn devices provides an opportunity for cardiovascular medicine. However, the accuracy of commercial devices is largely unknown. The aim of this work is to assess the accuracy of seven commercially available wrist-worn devices in estimating heart rate (HR) and energy expenditure (EE) and to propose a wearable sensor evaluation framework. We evaluated the Apple Watch, Basis Peak, Fitbit Surge, Microsoft Band, Mio Alpha 2, PulseOn, and Samsung Gear S2. Participants wore devices while being simultaneously assessed with continuous telemetry and indirect calorimetry while sitting, walking, running, and cycling. Sixty volunteers (29 male, 31 female, age 38 ± 11 years) of diverse age, height, weight, skin tone, and fitness level were selected. Error in HR and EE was computed for each subject/device/activity combination. Devices reported the lowest error for cycling and the highest for walking. Device error was higher for males, greater body mass index, darker skin tone, and walking. Six of the devices achieved a median error for HR below 5% during cycling. No device achieved an error in EE below 20 percent. The Apple Watch achieved the lowest overall error in both HR and EE, while the Samsung Gear S2 reported the highest. In conclusion, most wrist-worn devices adequately measure HR in laboratory-based activities, but poorly estimate EE, suggesting caution in the use of EE measurements as part of health improvement programs. We propose reference standards for the validation of consumer health devices ( http://precision.stanford.edu/ ).
机译:通过腕戴式设备测量身体活动的能力为心血管医学提供了机会。但是,商用设备的准确性很大程度上未知。这项工作的目的是评估七个市场上可买到的腕戴设备在估算心率(HR)和能量消耗(EE)方面的准确性,并提出一种可穿戴式传感器评估框架。我们评估了Apple Watch,Basis Peak,Fitbit Surge,Microsoft Band,Mio Alpha 2,PulseOn和Samsung Gear S2。参与者戴着设备,同时坐着,步行,跑步和骑自行车时要进行连续遥测和间接量热,同时进行评估。选择了年龄,身高,体重,肤色和健康水平各异的60名志愿者(29名男性,31名女性,年龄38±11岁)。针对每个受试者/设备/活动组合计算HR和EE的错误。设备报告的骑行错误率最低,而行走的错误率最高。男性的装置错误较高,体重指数较高,肤色较深,并且走路。六种设备在循环过程中HR的中值误差低于5%。没有任何设备的EE错误低于20%。在HR和EE方面,Apple Watch的整体错误率最低,而Samsung Gear S2则是最高的。总之,大多数腕戴式设备可以在实验室活动中充分测量心率,但对EE的估算却很差,这建议在健康改进计划中使用EE测量时要谨慎。我们提出了用于验证消费者保健设备的参考标准(http://precision.stanford.edu/)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号