Increased uptake by stomach, thyroid, and liver incidental to bone scanning suggests that 99mTc-pertechnetate (99mTcO4-) and reduced hydrolyzed technetiumtin colloid [99mTc(OH)4 ?· Sn (OH)2] are radiochemical impurities present in Sn-diphosphonate (EHDP) and Sn-pyrophosphate (PP). The amount of uptake in stomach, salivary glands, and thyroid is due to the presence of pertechnetate and is related to the time interval between preparation and administration. An evaluation of the bone agents 99mTc-EHDP and 99mTc-PP showed increasing amounts of 99mTcO4- during a 5-h interval, while 99mTc-EHDP with stabilizer was unchanged. In contrast, the colloid concentration was the same in all agents tested and did not change with time. Administration of 99mTc-EHDP or 99mTc-PP within 2 h after preparation will reduce the amount of free pertechnetate and improve bone-imaging quality. Our data suggest that a stabilizer should be used when the interval from preparation to administration is expected to exceed 2h.
机译:骨骼扫描附带的胃,甲状腺和肝的摄取增加表明 99m Tc-高tech酸酯( 99m TcO 4 -)并降低了水解的tech胶体[ 99m Tc(OH) 4 ?·Sn(OH) 2 ]是二膦酸锡(EHDP)和锡中存在的放射化学杂质-焦磷酸盐(PP)。胃,唾液腺和甲状腺的摄取量是由于高tech酸盐的存在,与制备和给药之间的时间间隔有关。对骨制剂 99m Tc-EHDP和 99m Tc-PP的评估显示, 99m TcO 4 的数量增加-在5小时间隔内,带有稳定剂的 99m Tc-EHDP保持不变。相反,在所有测试的试剂中,胶体浓度是相同的,并且不会随时间变化。制备后2小时内施用 99m Tc-EHDP或 99m Tc-PP可以减少游离高ate酸盐的量并改善骨成像质量。我们的数据表明,从制备到给药的时间间隔预计超过2小时时,应使用稳定剂。