...
首页> 外文期刊>Journal of Environmental Analytical Chemistry >Analysis of 19 preservatives in Polyvinyl Alcohol Cooling Towels Used in Japanby High Performance Liquid Chromatography with Photo Diode Array Detector
【24h】

Analysis of 19 preservatives in Polyvinyl Alcohol Cooling Towels Used in Japanby High Performance Liquid Chromatography with Photo Diode Array Detector

机译:光电二极管阵列检测器高效液相色谱法分析日本使用的聚乙烯醇冷却毛巾中的19种防腐剂

获取原文
           

摘要

The cases of contact dermatitis due to using polyvinyl alcohol (PVA) towel containing isothiazolinone preservatives have been reported in Japan and we had investigated the concentrations of isothiazolinones and the removal of these preservatives from PVA towels by washing before initial use in the previous study conducted from 2011 to 2012. However, the clinical information regarding contact dermatitis due to using PVA cooling towels containing other preservatives was provided from the supplier of PVA towel in the summer of 2013. Thus, we analyzed 19 preservatives in 21 PVA towels by high performance liquid chromatography with photo diode array detector in this study. A good separation of these preservatives was observed using InertSustain? Phenyl column and 0.1 % formic acid solution as the mobile phase. 2-Methyl-4-isothiazolin-3-one and 5-chloro-2-methyl-4- isothiazolin-3-one were detected in 16 samples, including the sample which was sold in a dry condition; the concentrationsof these substances ranged from 7.9-84 μg/g-wet and 9.5-173 μg/g-wet, respectively (2.9 μg/g-dry and 9.3 μg/g-dry, respectively). 2-n-Octyl-4-isothiazolin-3-one was detected in one sample (484 μg/g-wet). 2- Bromo-2-nitropropane-1,3-diol (BP) was detected in 15 samples, including the sample which was sold in a dry condition; its concentration ranged from 68-2303 μg/g-wet (160 μg/g-dry). 2-Phenoxyethanol (PE) and benzoic acid (BA) were detected in 3 and 2 samples, and their concentrations ranged from 99-3171 μg/g-wet and 1896-23043 μg/g-wet. Other preservatives were not detected. Although isothiazolinone preservatives were detected in 17 samples, the product notes of 10 products, including the product with clinical information, did not describe about the use of isothiazolinone preservatives. Since PVA cooling towels in contact with human skin for a long time, the PVA cooling towels should be used with caution, especially on patients who are already sensitive to isothiazolinone preservatives. Furthermore, we evaluated the effectiveness of the washing process on the removal of BP, PE, and BA from the PVA towels before their initial use. The results of this laboratory-simulated washing procedure suggest that contact dermatitis is likely not related to the presence of BP, PE, and BA in washed PVA towels.
机译:在日本已有报道,由于使用含异噻唑啉酮防腐剂的聚乙烯醇(PVA)毛巾而导致接触性皮炎的病例,我们在先前的研究中首次使用前调查了异噻唑啉酮的浓度并通过洗涤从PVA毛巾中去除了这些防腐剂。 2011年至2012年。但是,由于使用了含有其他防腐剂的PVA冷却巾而引起的接触性皮炎的临床信息是2013年夏天由PVA毛巾的供应商提供的。因此,我们通过高效液相色谱法分析了21根PVA毛巾中的19种防腐剂。在本研究中使用光电二极管阵列检测器。使用InertSustain?可以很好地分离出这些防腐剂。苯基柱和0.1%甲酸溶液作为流动相。在16个样品中检测到2-甲基-4-异噻唑啉-3-酮和5-氯-2-甲基-4-异噻唑啉-3-酮,其中包括在干燥条件下出售的样品。这些物质的浓度分别为7.9-84微克/克湿和9.5-173微克/克湿(分别为2.9微克/克干和9.3微克/克干)。在一个样品(484μg/ g-湿)中检测到2-n-Octyl-4-isothiazolin-3-one。在15个样品中检测到2-溴-2-硝基丙烷-1,3-二醇(BP),包括以干燥条件出售的样品;浓度范围为68-2303μg/ g湿(160μg/ g干)。在3个和2个样品中检测到2-苯氧基乙醇(PE)和苯甲酸(BA),其浓度范围为99-3171μg/ g湿和1896-23043μg/ g湿。未检测到其他防腐剂。尽管在17个样品中检出了异噻唑啉酮防腐剂,但10种产品的产品注释(包括具有临床信息的产品)并未描述异噻唑啉酮防腐剂的使用。由于PVA冷却巾长时间与人体皮肤接触,因此应谨慎使用PVA冷却巾,尤其是对于已经对异噻唑啉酮防腐剂敏感的患者。此外,我们评估了洗涤过程在首次使用前从PVA毛巾上去除BP,PE和BA的有效性。该实验室模拟洗涤程序的结果表明,接触后的皮炎可能与洗涤后的PVA毛巾中BP,PE和BA的存在无关。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号