Background We explore the use of a clinical orthovoltage X-ray treatment unit as a small-animal radiation therapy system in a tumoral model of cervical cancer. Methods Nude mice were subcutaneously inoculated with 5 × 106 HeLa cells in both lower limbs. When tumor volume approximated 200 mm3 treatment was initiated. Animals received four 2 mg/kg intraperitoneal cycles (1/week) of cisplatin and/or 6.25 mg/kg of gemcitabine, concomitant with radiotherapy. Tumors were exposed to 2.5 Gy/day nominal surface doses (20 days) of 150 kV X-rays. Lead collimators with circular apertures (0.5 to 1.5 cm diameter) were manufactured and mounted on the applicator cone to restrict the X-ray beam onto tumors. X-ray penetration and conformality were evaluated by measuring dose at the surface and behind the tumor lobe by using HS GafChromic film. Relative changes in tumor volume (RTV) and a clonogenic assay were used to evaluate the therapeutic response of the tumor, and relative weight loss was used to assess toxicity of the treatments. Results No measurable dose was delivered outside of the collimator apertures. The analysis suggests that dose inhomogeneities in the tumor reach up to ± 11.5% around the mean tumor dose value, which was estimated as 2.2 Gy/day. Evaluation of the RTV showed a significant reduction of the tumor volume as consequence of the chemoradiotherapy treatment; results also show that toxicity was well tolerated by the animals. Conclusion Results and procedures described in the present work have shown the usefulness and convenience of the orthovoltage X-ray system for animal model radiotherapy protocols.
机译:背景技术我们探索在子宫颈癌的肿瘤模型中使用临床正电压X射线治疗仪作为小动物放射治疗系统。方法对裸鼠皮下接种双下肢5×10 6 HeLa细胞。当肿瘤体积大约为200 mm 3 时开始治疗。动物接受了四个2 mg / kg的腹膜内周期(1 /周)顺铂和/或6.25 mg / kg的吉西他滨,并伴有放疗。将肿瘤暴露于2.5 gy /天的标称表面剂量(20天)的150 kV X射线中。制造具有圆形孔(直径0.5至1.5厘米)的铅准直仪,并将其安装在敷料锥上,以将X射线束限制在肿瘤上。使用HS GafChromic膜通过测量肿瘤叶表面和后方的剂量来评估X射线穿透和适形性。肿瘤体积(RTV)的相对变化和克隆形成试验用于评估肿瘤的治疗反应,相对体重减轻用于评估治疗的毒性。结果在准直仪孔的外面没有可测量的剂量。分析表明,肿瘤中的剂量不均匀性在平均肿瘤剂量值(估计为2.2 Gy /天)附近高达±11.5%。对RTV的评估显示,放化疗治疗后肿瘤体积显着减少。结果还表明毒性被动物很好地耐受。结论当前工作中描述的结果和程序已经显示了正电压X射线系统对动物模型放疗方案的有用性和便利性。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号