首页> 外文期刊>Journal of Applied Oral Science >Effect of leaching residual methyl methacrylate concentrations on in vitro cytotoxicity of heat polymerized denture base acrylic resin processed with different polymerization cycles
【24h】

Effect of leaching residual methyl methacrylate concentrations on in vitro cytotoxicity of heat polymerized denture base acrylic resin processed with different polymerization cycles

机译:浸出残留甲基丙烯酸甲酯浓度对不同聚合周期加工的热聚合义齿基丙烯酸树脂体外细胞毒性的影响

获取原文
           

摘要

OBJECTIVES: Residual methyl methacrylate (MMA) may leach from the acrylic resin denture bases and have adverse effects on the oral mucosa. This in vitro study evaluated and correlated the effect of the leaching residual MMA concentrations ([MMA]r) on in vitro cytotoxicity of L-929 fibroblasts. MATERIAL AND METHODS: A total of 144 heat-polymerized acrylic resin specimens were fabricated using 4 different polymerization cycles: (1) at 74oC for 9 h, (2) at 74oC for 9 h and terminal boiling (at 100oC) for 30 min, (3) at 74oC for 9 h and terminal boiling for 3 h, (4) at 74oC for 30 min and terminal boiling for 30 min. Specimens were eluted in a complete cell culture medium at 37oC for 1, 2, 5 and 7 days. [MMA]r in eluates was measured using high-performance liquid chromatography. In vitro cytotoxicity of eluates on L-929 fibroblasts was evaluated by means of cell proliferation using a tetrazolium salt XTT (sodium 3′-[1-phenyl-aminocarbonyl)-3,4-tetrazolium]bis(4-methoxy-6-nitro)benzenesulphonic acid) assay. Differences in [MMA]r of eluates and cell proliferation values between polymerization cycles were statistically analyzed by Kruskal-Wallis, Friedman and Dunn's multiple comparison tests. The correlation between [MMA]r of eluates and cell proliferation was analyzed by Pearson's correlation test (p<0.05). RESULTS: [MMA]r was significantly (p<0.001) higher in eluates of specimens polymerized with cycle without terminal boiling after elution of 1 and 2 days. Cell proliferation values for all cycles were significantly (p<0.01) lower in eluates of 1 day than those of 2 days. The correlation between [MMA]r and cell proliferation values was negative after all elution periods, showing significance (p<0.05) for elution of 1 and 2 days. MMA continued to leach from acrylic resin throughout 7 days and leaching concentrations markedly reduced after elution of 1 and 2 days. CONCLUSION: Due to reduction of leaching residual MMA concentrations, use of terminal boiling in the polymerization process for at least 30 min and water storage of the heat-polymerized denture bases for at least 1 to 2 days before denture delivery is clinically recommended for minimizing the residual MMA and possible cytotoxic effects.
机译:目的:残留的甲基丙烯酸甲酯(MMA)可能会从丙烯酸树脂义齿基料中浸出,并对口腔粘膜产生不利影响。这项体外研究评估了浸出残留MMA浓度([MMA] r)对L-929成纤维细胞的体外细胞毒性的影响,并将其关联起来。材料与方法:使用4个不同的聚合周期,共制备了144个热聚合丙烯酸树脂样品:(1)在74oC下加热9h,(2)在74oC下加热9h,最终沸腾(在100oC下加热30min), (3)在74oC下加热9小时并终沸腾3 h,(4)在74oC下加热30分钟并终沸腾30分钟。将标本在完整的细胞培养基中于37oC洗脱1、2、5和7天。使用高效液相色谱法测定洗脱液中的[MMA] r。洗脱液对L-929成纤维细胞的体外细胞毒性通过使用四唑盐XTT(3'-[1-苯基-氨基羰基钠] -3,4-四唑]双(4-甲氧基-6-硝基)的细胞增殖来评估)苯磺酸)测定法。通过Kruskal-Wallis,Friedman和Dunn的多重比较测试对聚合周期之间洗脱液[MMA] r和细胞增殖值的差异进行统计分析。洗脱液的[MMA] r与细胞增殖之间的相关性通过皮尔森相关性检验进行了分析(p <0.05)。结果:在经过1天和2天洗脱而没有循环沸腾的循环聚合的样品洗脱液中,[MMA] r显着较高(p <0.001)。 1天洗脱液中所有周期的细胞增殖值均明显低于2天(p <0.01)。在所有洗脱期后,[MMA] r与细胞增殖值之间的相关性为负,显示1天和2天洗脱的显着性(p <0.05)。 MMA在整个7天中继续从丙烯酸树脂中浸出,洗脱1天和2天后浸出浓度显着降低。结论:由于减少了浸出残留的MMA浓度,在临床上建议在义齿交付之前在聚合过程中使用末端沸腾至少30分钟,并在热聚合义齿基料中储水至少1至2天,以减少义齿的附着。残留的MMA和可能的细胞毒性作用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号