首页> 外文期刊>Journal of Dental Materials and Techniques >Effect of Storage Media and Sterilization Method on Shear Bond Strength of Composite to Enamel of Extracted Teeth
【24h】

Effect of Storage Media and Sterilization Method on Shear Bond Strength of Composite to Enamel of Extracted Teeth

机译:储存介质和灭菌方法对复合材料对拔牙牙釉质剪切粘结强度的影响

获取原文
           

摘要

Aim: To evaluate the effect of storage media and autoclaving on shear bond strength of composite to enamel. Materials and Methods: 100 human premolars were randomly divided into ten groups of ten as follows: C: freshly extracted teeth. A: Autoclaved freshly extracted teeth. CH-6: 6 month storage in 0.5 % chloramine T. CA-6: 6 month storage in 0.5 % chloramine T + autoclaving. T-6: 6 month storage in 0.04 % thymol. TA-6: 6 month storage in 0.4% thymol + autoclaving. Ch-12:12 month storage in 0.5 % chloramine T. CA-12: 12 month storage in 0.5 % chloramine T + autoclaving. T-12: 12 month storage in 0.4% thymol. TA-12:12 month storage in 0.4% thymol + autoclaving. One composite cylinder was bonded on each specimen for evaluation of shear bond strength (SBS) and failure modes. Data were analyzed using three-way ANOVA, Tukey’s post hoc and Chi square tests and the level of significance was set at P= 0.05. Results: Autoclaving and storage media had no significant effect on SBS (P-value = 0.818 for storage media and P-value = 0.221 for autoclaving). However, storage duration significantly changed SBS (P-value = 0.00). There were no correlations among the variables (P-value > 0.05). Storage media and duration had no significant effect on failure modes (P-value > 0.05), but autoclaving significantly increased cohesive failure of enamel (P-value =0.039). Conclusion: Storage of teeth in chloramine T and thymol had no significant effect on bond strength to enamel. Although autoclaving of specimens may not alter bond strength, it can significantly increase the cohesive failure of enamel.
机译:目的:评估储存介质和高压灭菌对复合材料与瓷釉的剪切粘结强度的影响。材料与方法:将100颗人类前磨牙随机分为10组,每组10条,如下所示:C:新鲜拔牙。答:高压灭菌的新鲜拔牙。 CH-6:在0.5%的氯胺T中保存6个月。CA-6:在0.5%的氯胺T中+保存6个月。 T-6:在0.04%百里酚中储存6个月。 TA-6:在0.4%百里酚+高压灭菌中保存6个月。将Ch-12:12个月储存在0.5%的氯胺T中。CA-12:将12个月储存在0.5%的氯胺T中+高压灭菌。 T-12:在0.4%百里酚中储存12个月。 TA-12:12个月以0.4%百里酚+高压灭菌保存。将一个复合圆柱体粘结在每个样品上,以评估剪切粘结强度(SBS)和破坏模式。使用三向方差分析,Tukey事后检验和卡方检验分析数据,显着性水平设置为P = 0.05。结果:高压灭菌和存储介质对SBS没有显着影响(存储介质的P值= 0.818,高压灭菌的P值= 0.221)。但是,存储时间显着改变了SBS(P值= 0.00)。变量之间没有相关性(P值> 0.05)。存储介质和持续时间对破坏模式没有显着影响(P值> 0.05),但高压灭菌处理显着增加了搪瓷的内聚破坏性(P值= 0.039)。结论:在氯胺T和百里酚中储存牙齿对牙釉质的粘结强度没有显着影响。尽管对样品进行高压灭菌不会改变粘结强度,但会显着增加搪瓷的内聚力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号