首页> 外文期刊>Journal of Conservative Dentistry >Two years survivability of VITA 3D master shade matching guides after disinfection with isopropyl alcohol: An in vitro study
【24h】

Two years survivability of VITA 3D master shade matching guides after disinfection with isopropyl alcohol: An in vitro study

机译:异丙醇消毒后VITA 3D主色调匹配指南的两年生存期:一项体外研究

获取原文
           

摘要

Background: Dental shade guides are used before restorative and prosthodontic procedures for the evaluation of tooth color. The spectral coverage of the specific shaded guide and a clinician's experience in shade matching are the two most important factors for a clinically viable shade match of the restoration to the given tooth. Repeated disinfection of the shade guide with disinfectant lead to a clinically significant difference of the shade to be matched, finally resulting in a clinically unacceptable prosthesis. The purpose of this study is to evaluate the effects of disinfection on various shade tabs of VITA 3D Master Shade guide after being subjected to 2 years of simulated disinfection with 70% isopropyl alcohol. Methodology: Two sets of VITA 3-D Master Shade Guides were used. One set of each shade guide was assessed after simulated use and surface disinfection with 70% isopropyl alcohol (test group), while the other full set was subjected to cleansing with distilled water (control group). Spectrophotometer was used to measure each of the shade tabs. Readings were recorded at regular intervals of 120, 240, 360, 480, 600, 720, 840, and 960 disinfection cycles. The ΔE values obtained were used to examine the color difference. Results: There was a significant difference in terms of ΔE between the shade tabs of control and test groups of VITA 3D Master shade guides after 960 cycles of disinfection. The change in mean ΔE was more in the test specimens in the shade tabs of VITA 3D Master Shade Guide tabs than the control specimens. These results are of statistical significance, but they might not be of any clinical significance. Conclusion: There was a statistically significant but clinically nonsignificant color change in the shade tabs of VITA 3D Master shade guides after 2 years of simulated use and disinfection with 70% isopropyl alcohol.
机译:背景:在修复和修复牙齿之前,需要使用牙科阴影引导器来评估牙齿的颜色。特定阴影指南的光谱覆盖范围和临床医生在阴影匹配方面的经验是使修复体与给定牙齿在临床上可行的阴影匹配的两个最重要因素。用消毒剂对遮光罩引导件进行重复消毒会导致要匹配的遮光罩在临床上有显着差异,最终导致临床上无法接受的假体。这项研究的目的是评估在用70%异丙醇进行2年模拟消毒后,消毒对VITA 3D Master Shade Guide的各种阴影标签的影响。方法:使用了两组VITA 3-D Master Shade Guides。在模拟使用和用70%异丙醇进行表面消毒后,评估了每套遮光罩的一套(测试组),而另一套则用蒸馏水清洗(对照组)。使用分光光度计测量每个阴影选项卡。定期以120、240、360、480、600、720、840和960个消毒周期记录读数。将获得的ΔE值用于检查色差。结果:在经过960次消毒后,VITA 3D Master遮阳板的对照组和测试组的遮阳板之间的ΔE差异显着。在VITA 3D主阴影指南选项卡的阴影选项卡中的测试样本中,平均ΔE的变化大于对照样本。这些结果具有统计学意义,但可能没有任何临床意义。结论:经过2年模拟使用并用70%异丙醇消毒后,VITA 3D Master阴影指南的阴影选项卡上的统计学变化具有统计学意义,但临床上无统计学意义。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号