...
首页> 外文期刊>Journal of Conservative Dentistry >Effect of four different surface treatments on shear bond strength of three porcelain repair systems: An in vitro study
【24h】

Effect of four different surface treatments on shear bond strength of three porcelain repair systems: An in vitro study

机译:四种不同表面处理对三种瓷质修复系统的剪切粘结强度的影响:体外研究

获取原文
           

摘要

Background:Ceramic fracture in metal ceramic restorations are serious and pose an aesthetic and functional dilemma both for the patients and the dentist. This has created a demand for the development of practical repair options which do not necessitate the removal and remake of entire restorations.Aim:To evaluate and compare the effect of four different surface treatments on shear bond strength of metal ceramic specimens with three commercially available porcelain repair systems.Materials and Methods:Specimens were fabricated with a base-metal ceramic alloy and divided into three groups, to evaluate three porcelain repair systems. Each group was divided into four subgroups based on surface treatment (A) sandblasting, (B) sandblasting followed by etching with 9% HF (Hydrofluoric acid) on surrounding ceramic, (C) Use of a diamond bur on exposed metal followed by etching with 37% H3PO4 and (D) Control groups (D1, D2, D3 for three groups of porcelain repair system which was not subjected to further treatment after finishing with 240 grit silicon carbide paper grinding. Shear bond strength of each group of specimens based on surface treatment were evaluated with a universal testing machine after storing in distilled water for 7 days. One way ANOVA and Tukey-HSD procedure were used to compare the mean values between and among the groups.Results:The mean shear bond strength of group III (10.402 ± 1.055) were significantly higher than group I (8.647 ± 0.990) and group II (8.099 ± 0.600) for all surface treatments. However the mean values of shear bond strength of sub-group A were significantly higher than sub-group C and D but were not significantly higher than sub-group B.Conclusion:The results of this study suggest that in fractured metal ceramic restorations the exposed metal surface treated with sandblasting or sandblasting and etching the surrounding ceramic surface with HF can increase the shear bond strength of the repaired metal ceramic area. Porcelain repair systems which contain hybrid composites and 4-META as primer had increased bond strength.
机译:背景:金属陶瓷修复体中的陶瓷骨折很严重,给患者和牙医带来了美学和功能上的困境。这就提出了开发实用修复方案的需求,这些修复方案不需要拆除和重新制作整个修复体。目的:评估和比较四种不同表面处理对金属陶瓷样品与三种市售瓷器的剪切粘结强度的影响材料和方法:用贱金属陶瓷合金制造试样,并分为三组,以评估三个瓷修复系统。根据表面处理将每组分为四个子组:(A)喷砂,(B)喷砂,然后在周围的陶瓷上用9%HF(氢氟酸)蚀刻,(C)在裸露的金属上使用金刚石钻,然后用三组瓷修复系统的37%H3PO4和(D)对照组(D1,D2,D3)在用240粒度的碳化硅纸研磨完成后未作进一步处理,每组试样的抗剪强度均基于表面将试验组在蒸馏水中保存7天后,用通用试验机进行评估,采用ANOVA和Tukey-HSD方法比较各组之间的平均值。结果:第三组的平均剪切粘结强度(10.402)。在所有表面处理中,±1.055)均显着高于I组(8.647±0.990)和II组(8.099±0.600),但A组的剪切粘结强度平均值明显高于C组。结论:本研究结果表明,在断裂的金属陶瓷修复体中,经喷砂处理或喷砂处理的裸露金属表面,以及用HF蚀刻周围的陶瓷表面可以提高剪切粘结强度修复的金属陶瓷区域。包含杂化复合材料和4-META作为底漆的瓷修复系统具有增强的粘结强度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号