A comparative study of software programmes for cross-sectional skeletal muscle and adipose tissue measurements on abdominal computed tomography scans of rectal cancer patients

机译:直肠癌患者腹部计算机断层扫描的骨骼肌和脂肪组织横断面测量软件程序的比较研究

获取原文
           

摘要

Abstract Background The association between body composition (e.g. sarcopenia or visceral obesity) and treatment outcomes, such as survival, using single-slice computed tomography (CT)-based measurements has recently been studied in various patient groups. These studies have been conducted with different software programmes, each with their specific characteristics, of which the inter-observer, intra-observer, and inter-software correlation are unknown. Therefore, a comparative study was performed. Methods Fifty abdominal CT scans were randomly selected from 50 different patients and independently assessed by two observers. Cross-sectional muscle area (CSMA, i.e. rectus abdominis, oblique and transverse abdominal muscles, paraspinal muscles, and the psoas muscle), visceral adipose tissue area (VAT), and subcutaneous adipose tissue area (SAT) were segmented by using standard Hounsfield unit ranges and computed for regions of interest. The inter-software, intra-observer, and inter-observer agreement for CSMA, VAT, and SAT measurements using FatSeg, OsiriX, ImageJ, and sliceOmatic were calculated using intra-class correlation coefficients (ICCs) and Bland?¢????Altman analyses. Cohen's ???o was calculated for the agreement of sarcopenia and visceral obesity assessment. The Jaccard similarity coefficient was used to compare the similarity and diversity of measurements. Results Bland?¢????Altman analyses and ICC indicated that the CSMA, VAT, and SAT measurements between the different software programmes were highly comparable (ICC 0.979?¢????1.000, P < 0.001). All programmes adequately distinguished between the presence or absence of sarcopenia (???o = 0.88?¢????0.96 for one observer and all ???o = 1.00 for all comparisons of the other observer) and visceral obesity (all ???o = 1.00). Furthermore, excellent intra-observer (ICC 0.999?¢????1.000, P < 0.001) and inter-observer (ICC 0.998?¢????0.999, P < 0.001) agreement for all software programmes were found. Accordingly, excellent Jaccard similarity coefficients were found for all comparisons (mean ?¢???¥ 0.964). Conclusions FatSeg, OsiriX, ImageJ, and sliceOmatic showed an excellent agreement for CSMA, VAT, and SAT measurements on abdominal CT scans. Furthermore, excellent inter-observer and intra-observer agreement were achieved. Therefore, results of studies using these different software programmes can reliably be compared.
机译:摘要背景最近,已在各个患者组中研究了基于单层计算机断层扫描(CT)的测量方法的身体成分(例如肌肉减少症或内脏肥胖症)与治疗结果(例如生存率)之间的关联。这些研究是使用不同的软件程序进行的,每个软件程序都有其特定的特征,其中观察者之间,观察者内部和软件之间的相关性是未知的。因此,进行了比较研究。方法从50例不同患者中随机选择50例腹部CT扫描,并由两名观察员独立评估。使用标准的Hounsfield单位对横断面肌肉区域(CSMA,即腹直肌,腹斜肌和横腹肌,脊柱旁肌肉和腰大肌),内脏脂肪组织面积(VAT)和皮下脂肪组织面积(SAT)进行分割范围并针对感兴趣的区域进行计算。使用类内相关系数(ICC)和Bland?¢ ??????计算使用FatSeg,OsiriX,ImageJ和sliceOmatic进行CSMA,VAT和SAT测量的软件间,观察员内部和观察员之间的一致性。奥特曼分析。 Cohen's o是根据肌肉减少症和内脏肥胖评估的一致性计算的。 Jaccard相似系数用于比较测量的相似性和多样性。结果Bland的Altman分析和ICC表明,不同软件程序之间的CSMA,VAT和SAT测量具有高度可比性(ICC 0.979≤1.000,P <0.001)。所有程序都充分地区分了肌肉减少症的存在与否(一名观察者为o = 0.88×0.96,另一观察者的所有比较为o = 1.00)和内脏肥胖症(全部≥5)。 o = 1.00)。此外,发现所有软件程序的观察者内观察者(ICC0.999≤1.000,P <0.001)和观察者间观察者(ICC0.998≤0.999,P <0.001)一致。因此,对于所有比较都发现了极好的Jaccard相似性系数(平均¢ 0.964)。结论FatSeg,OsiriX,ImageJ和sliceOmatic对腹部CT扫描的CSMA,VAT和SAT测量显示出极好的一致性。此外,观察员之间和观察员内部之间达成了良好的协议。因此,可以可靠地比较使用这些不同软件程序的研究结果。

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号