Tunnels have very severe air quality constraints that typically require good ventilation system. The process of removing air from any space by mechanical means is known as evacuation. Evacuation of exhaust and smoke in case of fire emergencies is very necessary to bring in fresh air as it leads to pressure and temperature build up which causes discomfort to the passengers travelling especially in long tunnels. Generally, in longitudinal ventilation, a jet blower fan enclosed in a cylindrical casing is used for ventilation. These jet fans accelerate the air by imparting it an impulse in the desired direction. The main aim is to optimize the design and replace the jet blower fan cylindrical enclosure by a CD Nozzle. The suction fan along with rotor is exactly placed at the throat of the nozzle. The modeling is done using CATIA V5 software and CFD flow and modal analysis is carried out using ANSYS V 15.0. Various parameters like pressure, temperature, density, humidity and mass flow rate of air are measured and compared with the conventional model by experimentation and the results are validated.
机译:隧道的空气质量非常严格,通常需要良好的通风系统。通过机械手段从任何空间去除空气的过程称为疏散。紧急情况下,疏散废气和烟雾对于引入新鲜空气非常必要,因为这会导致压力和温度升高,从而给乘车长途旅行的乘客带来不适。通常,在纵向通风中,使用封闭在圆筒形壳体中的喷气鼓风机进行通风。这些喷射风扇通过向所需方向施加脉冲来加速空气。主要目的是优化设计,并用CD喷嘴替换喷气鼓风机的圆柱形外壳。抽气扇与转子精确地放置在喷嘴的喉咙处。使用CATIA V5软件进行建模,并使用ANSYS V 15.0进行CFD流程和模态分析。测量了压力,温度,密度,湿度和空气质量流量等各种参数,并通过实验与常规模型进行了比较,并验证了结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号