This paper describes an automatic system which measures the effect of temperature variations on the response of ion-selective electrodes (hysteresis curves). The system is managed by a computer program which plots hysteresis curves following a pre-established temperature cycle, from setting and controlling the temperature of the water-bath, to acquiring the response potentials of up to five electrodes after temperature stabilization.
机译:本文介绍了一种自动系统,该系统可测量温度变化对离子选择电极响应(磁滞曲线)的影响。该系统由计算机程序管理,该计算机程序绘制从设置和控制水浴温度到预设温度循环后,直至获得温度稳定后最多五个电极的响应电位之后的预定温度循环后的磁滞曲线。