首页> 外文期刊>Trauma Case Reports >Early failure of a locked titanium plate in a proximal humeral fracture: Case report and metallurgic analysis
【24h】

Early failure of a locked titanium plate in a proximal humeral fracture: Case report and metallurgic analysis

机译:锁定钛板在肱骨近端骨折中的早期失败:病例报告和冶金分析

获取原文
           

摘要

Angular stability locking plates are commonly used in proximal humeral fractures, especially in old patients with osteoporotic bones. These implants show good results in short and midterm follow-up, but complications are not uncommon. Here we present a case report to describe a case of early failure of a proximal angular stability plate implanted in a 72?years old female with a highly unstable two part proximal humeral fracture. An optical and metallurgic analysis was also conducted to study the modalities of failure. We concluded that anatomic reduction and restoration of the medial cortical support are crucial in order to minimize the mechanical load on the bone–metal interface and to prevent mechanical failure, in particular when the fracture rim drop in the weak point of the plate that was found in the proximal two symmetric holes (Holes E).
机译:角稳定性锁定板通常用于肱骨近端骨折,尤其是老年骨质疏松患者。这些植入物在短期和中期随访中显示出良好的效果,但并发症并不少见。在这里,我们提供一个病例报告来描述一例近端角稳定板植入早期失败的病例,该板植入一位高度不稳定的两部分肱骨近端骨折的72岁女性中。还进行了光学和冶金分析,以研究失效的方式。我们得出的结论是,内侧皮质支撑的解剖复位和恢复对于最小化骨金属界面上的机械负荷并防止机械故障至关重要,特别是当发现骨折边缘在钢板的薄弱点下降时在近端有两个对称孔(孔E)。