The paper analyses the possibility of reducing the initial current of synchronous motor used for powering an excavator in an open coal-pit. The main generator group, which consists of three DC generators S = 1250 kW, reaches the torque moment through synchronous motor with salient poles usage, Sr = 1250 kW. The motor is accelerated as asynchronous squirrel cage motor, drawing attention to the machine acceleration period till the moment it enters synchronism. During this period, lasting up to 15 seconds, it is necessary to connect the rotor winding through a resistor, to start the acceleration as asynchronous motor and pull the machine into synchronism. After that, a synchronous motor powers the DC generators and operates as a synchronous compensator. The excitation circuits of electromotor were originally powered by the DC generators. Now, these systems are replaced by more efficient thyristor static converters. In this way, the excavator efficiency is increased, a faster response of excitation circuit is obtained and initial currents of synchronous motor are significantly reduced.
机译:本文分析了降低露天矿中为挖掘机供电的同步电动机初始电流的可能性。由三台直流发电机S = 1250 kW组成的主发电机组通过使用凸极的同步电动机Sr = 1250 kW达到转矩力矩。电动机像异步鼠笼电动机一样被加速,引起人们注意机器的加速时间,直到它进入同步状态为止。在此期间(长达15秒),有必要通过电阻器连接转子绕组,以异步电动机的形式启动加速并使电机进入同步状态。之后,由同步电动机为直流发电机供电,并作为同步补偿器工作。电动机的励磁电路最初由直流发电机供电。现在,这些系统已被更高效的晶闸管静态转换器所取代。这样,提高了挖掘机效率,获得了励磁电路的更快响应,并且显着降低了同步电动机的初始电流。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号