The main objective of the work reported here is to assess factors that could affect the outcome of a proposed open flame test for barrier fabrics (BF-open flame test). The BF-open flame test characterizes barrier effectiveness by monitoring the ignition of a flexible polyurethane foam (FPUF) layer placed in contact with the upper side of the barrier fabric, exposed to a burner flame from below. Particular attention is given to the factors that influence the ignitibility of the FPUF, including thermal resistance, permeability, and structural integrity of the barrier fabrics (BFs). A number of barrier fabrics, displaying a wide range of the properties, are tested with the BF-open flame test. Visual observations of the FPUF burning behavior and BF char patterns, in addition to heat flux measurements on the unexposed side of the barrier fabrics, are used to assess the protective performance of the BF specimen under the open flame test conditions. The temperature and heat transfer measurements on the unexposed side of the BF and subsequent ranking of BFs for their thermal protective performance suggest that the BF-open flame test does not differentiate barrier fabrics based on their heat transfer properties. A similar conclusion is reached with regard to BF permeability characterized at room temperature. However, the outcome of this BF-open flame test is found to be heavily influenced by the structural integrity of thermally degraded BF. The BF-open flame test, in its current form, only ignited FPUF when structural failure of the barrier was observed.
机译:本文报道的工作的主要目的是评估可能影响提议的阻隔织物明火测试(BF-明火测试)结果的因素。高炉明火测试通过监测与阻隔织物上侧接触的柔性聚氨酯泡沫(FPUF)层的着火性来表征阻隔效果,该泡沫从下面暴露于燃烧器火焰。特别要注意影响FPUF可燃性的因素,包括阻热织物(BFs)的耐热性,渗透性和结构完整性。使用BF-明火测试对许多具有广泛性能的阻隔织物进行了测试。目视观察FPUF燃烧行为和BF炭图案,以及在阻隔织物未暴露侧的热通量测量,还用于评估在明火测试条件下BF标本的防护性能。高炉未暴露侧的温度和传热测量以及随后的高炉热防护性能排名表明,高炉明火测试无法根据其传热性能区分阻隔织物。关于在室温下表征的BF渗透率,得出类似的结论。但是,发现该高炉明火测试的结果受热降解高炉的结构完整性的严重影响。当前状态的高炉明火测试仅在观察到屏障的结构故障时才点燃FPUF。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号