首页> 外文期刊>Science Journal of Energy Engineering >Algorithm for the Performance Evaluation of Three Selected Wind Energy Conversion Systems (WECS) for Electricity Generation in Minna, Nigeria
【24h】

Algorithm for the Performance Evaluation of Three Selected Wind Energy Conversion Systems (WECS) for Electricity Generation in Minna, Nigeria

机译:尼日利亚明纳的三种选定风能发电系统(WECS)的性能评估算法

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Most of the wind energy conversion systems are failing in many developing countries such as Nigeria due to poor and un-appropriate site selection. Ten years (2001-2010) daily average wind speed data measured at 10m height for Minna (9.6°N, 6.6°E and 251m) were obtained from Nigerian Meteorological Agency (NIMET) and the characteristics of the three small scale wind energy conversion systems with power rating of 1, 1.5 and 3.0 kW obtained from the manufacturers websites were used in this study for the performance evaluation of three selected wind energy conversion system (WECS). The performance of the selected WECS were compared using the capacity factors obtained for the turbines from the algorithms developed, that combine the daily average wind speed and standard deviation for the location with the selected turbines characteristics provided by the manufacturers. The annual energy output for the WECS were found to be 1.37MWh, 1.23MWh and 2.53MWh with corresponding capacity factor of 18.8%, 11.2% and 8.4% respectively from e3001 (1kW), Ge-Power System 1.5SL (1.5kW) and Gv-3kW (3.0 kW). The e30001 (1kW) was observed to performed better with capacity factor of 18.8% as against 11.2% and 8.4% for Ge-Power system 1.5SL (1.5kW) and Gv-3kW (3.0 kW) respectively for Minna location.
机译:在许多发展中国家,例如尼日利亚,大多数风能转换系统都因选址不当和不当而出现故障。从尼日利亚气象局(NIMET)获得的明纳(9.6°N,6.6°E和251m)在10m高处测得的十年(2001-2010)日平均风速数据以及这三种小型风能转换系统的特性从制造商网站获得的功率分别为1、1.5和3.0 kW的功率用于本研究中的三个选定风能转换系统(WECS)的性能评估。使用从开发的算法中获得的涡轮机容量因子,比较了所选WECS的性能,这些因子将每日平均风速和位置的标准偏差与制造商提供的选定涡轮机特征相结合。 WECS的年发电量分别为e3001(1kW),Ge-Power System 1.5SL(1.5kW)和e3001(1kW),分别为1.37MWh,1.23MWh和2.53MWh,相应的容量系数分别为18.8%,11.2%和8.4%。 Gv-3kW(3.0 kW)。观察到e30001(1kW)的性能更好,容量因数为18.8%,而在Minna地区,Ge-Power系统1.5SL(1.5kW)和Gv-3kW(3.0 kW)分别为11.2%和8.4%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有