Accuracy of tablet splitting: Comparison study between hand splitting and tablet cutter

机译:压片精度:手压与压片机的对比研究

获取原文
           

摘要

Background: Tablet splitting is often used in pharmacy practice to adjust the administered doses. It is also used as a method of reducing medication costs. Objective: To investigate the accuracy of tablet splitting by comparing hand splitting vs. a tablet cutter for a low dose drug tablet. Methods: Salbutamol tablets (4mg) were chosen as low dose tablets. A randomly selected equal number of tablets were split by hand and a tablet cutter, and the remaining tablets were kept whole. Weight variation and drug content were analysed for salbutamol in 0.1N HCl using a validated spectrophotometric method. The percentages by which each whole tablet's or half-tablet's drug content and weight difference from sample mean values were compared with USP specification ranges for drug content. The %RSD was also calculated in order to determine whether the drugs met USP specification for %RSD. The tablets and half tablets were scanned using electron microscopy to show any visual differences arising from splitting. Results: 27.5% of samples differed from sample mean values by a percentage that fell outside of USP specification for weight, of which 15% from the tablet cutter and 25% from those split by hand fell outside the specifications. All whole tablets and half tablets met the USP specifications for drug content but the variation of content between the two halves reached 21.3% of total content in case of hand splitting, and 7.13% only for the tablet cutter. The %RSDs for drug content and weight met the USP specification for whole salbutamol tablets and the half tablets which were split by tablet cutter. The halves which were split by hand fell outside the specification for %RSD (drug content=6.43%, weight=8.33%). The differences were visually clear in the electron microscope scans. Conclusion: Drug content variation in half-tablets appeared to be attributable to weight variation occurring during the splitting process. This could have serious clinical consequences for medications with a narrow therapeutic-toxic range. On the basis of our results, we recommend to avoid tablet splitting whenever possible or the use of an accurate tablet splitting device when splitting cannot be avoided.
机译:背景:片剂分裂通常在药房实践中用于调整给药剂量。它也被用作降低药物成本的方法。目的:通过比较低剂量药物片剂的手分裂与片剂切割器的比较来研究片剂分裂的准确性。方法:选择沙丁胺醇片(4mg)作为低剂量片。用手和压片机将随机选择的相等数量的片剂分开,剩余的片剂保持完整。使用验证的分光光度法分析了0.1N HCl中沙丁胺醇的重量变化和药物含量。将每片全片或半片的药物含量和样品平均值的重量差所占的百分比与美国药典规定的药物含量范围进行比较。为了确定药物是否符合USP关于%RSD的规格,还计算了%RSD。使用电子显微镜对片剂和半片剂进行扫描,以显示由分裂引起的任何视觉差异。结果:27.5%的样品与样品均值之间的差异超出了USP重量规格,其中压片机的15%和手工分切的样品的25%超出了规格。所有全片和半片均符合美国药典关于药物含量的规范,但在手分开的情况下,两半之间的含量差异达到总含量的21.3%,而仅对于片剂切割机为7.13%。药物含量和重量的%RSDs符合美国药典中关于沙丁胺醇片和半片的所有规定,并用压片机将其分开。手工分割的一半不符合%RSD的规格(药物含量= 6.43%,重量= 8.33%)。在电子显微镜扫描中,差异明显可见。结论:半片剂中的药物含量变化似乎归因于分裂过程中发生的重量变化。对于治疗毒性范围狭窄的药物,这可能会产生严重的临床后果。根据我们的结果,我们建议尽可能避免片剂分裂,或者在无法避免分裂时使用精确的片剂分裂装置。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号