Objective To present the indications, technical aspects, and initial results of the first cases using Endo‐Model? implants in Brazil. Methods A prospective study was conducted. It included nine patients submitted to a total knee arthroplasty, of which six were primary and three were revisions, using exclusively the Endo‐Model? implant. These patients were followed for an average of 12 months and evaluated with functional scores, such as the Knee injury and Osteoarthritis Outcome Score (KOOS), Knee Society Score (KSS), and visual analog pain scale (VAS). Results There were statistically significant improvements in all scores evaluated in every patient. Only one complication occurred postoperatively (apraxia of the peroneal nerve) and did not require surgery revision. Conclusion The use of a rotating hinge implant for knee arthroplasty is a new option for complex cases with severe instability in Brazil; the initial results are satisfactory.
机译:目的介绍使用Endo-Model的首例病例的适应症,技术方面和初步结果?在巴西植入。方法进行前瞻性研究。其中包括9例接受全膝关节置换术的患者,其中6例是主要的,3例是翻修的,仅使用Endo-Model?注入。这些患者平均随访12个月,并通过功能评分进行评估,例如膝关节损伤和骨关节炎结果评分(KOOS),膝关节社会评分(KSS)和视觉模拟疼痛量表(VAS)。结果每位患者评估的所有评分均具有统计学上的显着改善。术后仅发生一种并发症(腓神经神经失弛缓),不需要手术矫正。结论对于巴西严重不稳定的复杂病例,旋转铰接植入物进行膝关节置换术是一种新选择。初步结果令人满意。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号