...
首页> 外文期刊>Nepalese Journal of Ophthalmology >Anterior Segment Optical Coherence Tomography Signs of Local Dilatation Effect of a Micro-Stent on Schlemm’s Canal
【24h】

Anterior Segment Optical Coherence Tomography Signs of Local Dilatation Effect of a Micro-Stent on Schlemm’s Canal

机译:前支架光学相干断层扫描的迹象表明,微支架对施莱姆管的局部扩张作用

获取原文
           

摘要

Introduction: The iStent inject? (Glaukos Corporation, CA, USA) is a relatively new device designed to be implanted ab-interno through the trabecular meshwork. This is, to the best of our knowledge, the first in-vivo description of a trabecular bypass device visualised with anterior segment optical coherence tomography (AS-OCT), and report of its structural effect on Schlemm’s canal. Case Report: A 74 year-old female patient suffering from long-standing primary open-angle glaucoma and nuclear sclerosis underwent cataract surgery combined with the implantation of two iStent injects?. Surgery was uncomplicated and achieved intraocular pressure (-1 mmHg)?and medication (-2 molecules) reduction at 6 months. Under AS-OCT (Spectralis OCT, Heidelberg Engineering AG, Germany) the stent appears as a 300 μm long hyper reflective hollow device within the trabecular meshwork. Approximately a third of it protruded into the anterior chamber. Profound OCT signal loss was notable within the shadow of the device. A second AS-OCT section 500 μm beside the microstent shows a markedly dilated Schlemm’s canal, with a major diameter of 390 μm. Discussions: This report confirms that AS-OCT is a suitable technique to assess microstent positioning, and provides a first report on the in-vivo appearance of a functioning stent. It also indicates that iStent injects? could have a tangible effect on adjacent portions of Schlemm’s canal with, in this case, a 220% increase in canal diameter compared to the observed average (122 μm). This suggests the IOP-lowering effect of trabecular bypass devices could rely on a dual mechanism involving Schlemm’s canal dilatation.
机译:简介:iStent注入? (美国加利福尼亚州格劳科斯公司(Glaukos Corporation,CA,美国))是一种相对较新的设备,旨在通过小梁网植入ab-interno。据我们所知,这是对小梁旁路装置的首次体内描述,该装置通过前节光学相干断层扫描(AS-OCT)可视化,并报告了其对Schlemm根管的结构影响。病例报告:一位患有长期原发性开角型青光眼和核硬化的74岁女性患者接受了白内障手术并植入了两种iStent注射液。手术不复杂,在6个月时眼内压(-1 mmHg)?和药物治疗(-2分子)减少。在AS-OCT(Spectralis OCT,德国海德堡工程公司,德国)下,该支架表现为小梁网中300μm长的超反射空心装置。它的大约三分之一伸入前房。在设备的阴影范围内,OCT信号明显丢失。微型支架旁的第二个AS-OCT区域(位于500μm处)显示出明显扩张的Schlemm根管,其大直径为390μm。讨论:该报告证实了AS-OCT是评估微支架定位的合适技术,并提供了有关功能性支架的体内外观的首次报告。它还表明iStent注入了吗?可能会对Schlemm运河的相邻部分产生明显影响,在这种情况下,与观察到的平均值(122μm)相比,运河直径增加了220%。这表明小梁旁路装置降低IOP的效果可能依赖于涉及Schlemm管扩张的双重机制。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号