...
首页> 外文期刊>Medical science monitor : >Clinical outcomes after cataract surgery with implantation of the Tecnis ZMB00 multifocal intraocular lens
【24h】

Clinical outcomes after cataract surgery with implantation of the Tecnis ZMB00 multifocal intraocular lens

机译:白内障手术后植入Tecnis ZMB00多焦点人工晶状体的临床结果

获取原文
           

摘要

Background The aim of this study was to evaluate visual performance, contrast sensitivity, and patient satisfaction in patients undergoing cataract surgery with bilateral implantation of the Tecnis ZMB00 diffractive multifocal IOL (intraocular lens). Material and Methods This was a prospective study of 40 eyes of 20 patients with an age range from 48 to 67 years and undergoing cataract surgery with implantation of the diffractive 1-piece IOL Tecnis ZMB00 (Abbott Medical Optics) in 1 eye and 3 weeks later in the other eye. The following parameters were evaluated at 3 and 6 months after the operation: binocular uncorrected distance, intermediate and near visual acuity (UDVA, UIVA, UNVA), uncorrected binocular photopic and mesopic distance and photopic near contrast sensitivity (CSV-1000), subjective symptoms, and patient satisfaction (VF-14). Results No significant change was observed in logMAR UDVA between 3 and 6 months postoperatively (–0.11±0.14 [i]vs.[/i] –0.10±0.13, p>0.05). In contrast, UNVA (0.06±0.12 [i]vs.[/i] –0.02±0.12, p=0.004) and UIVA (0.12±0.15 [i]vs.[/i] 0.07±0.11, p=0.005) in this period improved significantly. At 3 and 6 months after surgery, 85% of patients no longer needed to wear corrective lenses. Contrast sensitivity under different conditions was within normal age-matched limits, with significant improvements for some spatial frequencies at 3 and 6 months after surgery (p<0.04). Mean overall patient satisfaction was 9.39±1.06 and 9.19±1.20 (scale from 1 to 10, with 10 being the best score) at 3 and 6 months, respectively. Low level of halo perception was reported in 75% of patients. Conclusions The Tecnis ZMB00 IOL provides an effective restoration of the distance, intermediate, and near visual function, allowing patients to be totally free of need to wear corrective lenses and providing high levels of patient satisfaction.
机译:背景技术本研究的目的是评估双眼植入Tecnis ZMB00衍射多焦点IOL(人工晶状体)的白内障手术患者的视觉性能,对比敏感度和患者满意度。材料和方法这是一项前瞻性研究,对20例年龄在48至67岁的患者的40眼进行了研究,并在1眼和3周后接受了1片衍射IOL Tecnis ZMB00(Abbott Medical Optics)植入的白内障手术。在另一只眼中。在手术后3个月和6个月评估以下参数:双眼未矫正的距离,中度和近视力(UDVA,UIVA,UNVA),未矫正的双眼近视和中视距离以及近视的近视敏感度(CSV-1000),主观症状和患者满意度(VF-14)。结果术后3到6个月之间,logMAR UDVA没有观察到显着变化(–0.11±0.14 [i] vs。[/ i] –0.10±0.13,p> 0.05)。相比之下,UNVA(0.06±0.12 [i] vs。[/ i] –0.02±0.12,p = 0.004)和UIVA(0.12±0.15 [i] vs。[/ i] 0.07±0.11,p = 0.005)这一时期明显改善。术后3个月和6个月,不再有85%的患者戴矫正眼镜。在不同条件下的对比敏感性在正常的年龄匹配范围内,并且在术后3个月和6个月时某些空间频率有了显着改善(p <0.04)。在3个月和6个月时,患者的总体平均满意度分别为9.39±1.06和9.19±1.20(从1到10,其中10分是最高分)。据报道75%的患者光晕知觉水平较低。结论Tecnis ZMB00 IOL可有效恢复远,中和近视功能,使患者完全无需配戴矫正镜,并能使患者满意。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号