Hearing threshold prediction with Auditory Steady State Responses and estimation of correction functions to compensate for differences with behavioral data, in adult subjects. Part 1: Audera and CHARTR EP devices

机译:听觉稳态反应的听觉阈值预测和校正功能的估计,以补偿成人受试者与行为数据的差异。第1部分:Audera和CHARTR EP设备

获取原文
           

摘要

Background:The objective of the study was the evaluation and comparison of hearing threshold values extrapolated from Auditory Steady State Responses, using 2 commercial systems and the estimation of correction factors applicable to the ASSR data.Material/Methods:One hundred ten subjects participated to the study. All subjects were initially examined with otoscopy, pure-tone audiometry and admittance. Data were acquired by 2 clinical systems the Audera (Viasys) and the CHARTR EP (ICS), using identical protocols. The acoustic stimuli consisted of single carrier frequencies at 1000, 2000 and 4000 Hz modulated at 40 Hz.Results:The data show that the threshold estimates from both devices differ significantly from the measured behavioral thresholds. The ICS device presented significantly larger mean-ASSR estimated hearing level values at the tested frequencies, implying an underestimation of the hearing threshold. Both sets of prediction errors overestimated hearing levels for the normal group. The prediction errors were in all cases greater for the Audera than for the ICS.Conclusions:The errors encountered in the estimates of the 2 widely-used commercial devices suggest that the current ASSR protocols are not ready for a wide-range use and that significant developments in the area of threshold prediction / precision are necessary. If, on the other-hand, the ASSR predicted threshold is used on a purely consulting basis, as in hearing-aid fitting, then such errors might be acceptable in a clinical setting.
机译:背景:本研究的目的是使用2种商业系统评估和比较听觉稳态反应推断出的听力阈值,并估算适用于ASSR数据的校正因子。材料/方法:一百零一名受试者参加了这项研究。研究。最初对所有受试者进行耳镜检查,纯音测听和导纳检查。使用相同的协议,通过2个临床系统Audera(Viasys)和CHARTR EP(ICS)获取数据。声刺激由以40 Hz调制的1000、2000和4000 Hz的单载波频率组成。结果:数据表明,两种设备的阈值估计值与测量的行为阈值有很大差异。 ICS设备在测试频率下呈现出明显更大的平均ASSR估计听力水平值,这意味着对听力阈值的低估。两组预测误差均高估了正常人群的听力水平。结论:在所有情况下,Audera的预测误差都比ICS大。阈值预测/精度领域的发展是必要的。另一方面,如果在纯辅助咨询的基础上使用ASSR预测阈值(如在助听器验配中),则这种误差在临床环境中可能是可接受的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号