...
首页> 外文期刊>European spine journal >Axial T1ρ MRI as a diagnostic imaging modality to quantify proteoglycan concentration in degenerative disc disease
【24h】

Axial T1ρ MRI as a diagnostic imaging modality to quantify proteoglycan concentration in degenerative disc disease

机译:轴向T1ρMRI作为诊断性成像方式以量化变性椎间盘疾病中蛋白聚糖的浓度

获取原文
           

摘要

PurposeThe aim of the study was to investigate if axial T1ρ MR images had similar accuracy as established sagittal T1ρ MRI for the assessment of proteoglycan concentration and content in intervertebral degenerated discs (IDDs).MethodsT1ρ and T2-weighted MR images of 12 intervertebral discs (IVDs) from 3 harvested human lumbar spines (levels L1–L2 to L5–S1) were grouped across their degenerative grade (Pfirrmann scores) and analyzed using a 3T MRI scanner in the axial and sagittal views. Post-processing of axial T1ρ-weighted images was performed using a Wiener filter. Median axial T1ρ values for traced regions of interest (ROIs) on color maps were compared against ROIs in the corresponding location in the sagittal plane of each disc. Assessment of sulfated glycosaminoglycans (GAGs) content was also performed.ResultsComparison of post Wiener filtered mid-axial T1ρ values in the NP with corresponding mid-sagittal values revealed no statistical difference (P??0.05). Higher axial T1ρ and biochemically measured GAGs content corresponded to a lower Pfirrmann grading of the IVDs. A strong association between the T1ρ values and the GAG contents was observed (r?=?0.85, P?=?0.0002).ConclusionsThe axial T1ρ methodology was validated against sagittal T1ρ providing an augmented spatial representation of IVD and can facilitate localization of focal degeneration within IVDs. T1ρ values provided a better granularity assessment of degenerative disc disease as it correlated with proteoglycan concentration. Thus, Wiener filtering is an effective tool for removing noise from T1ρ-weighted axial MR images...
机译:目的本研究旨在研究轴向T1ρMR图像是否具有与既定的矢状T1ρMRI相似的准确性,以评估椎间盘退变盘(IDD)中的蛋白聚糖浓度和含量。方法12椎间盘(IVD)的T1ρ和T2加权MR图像)从3个收获的人类腰椎(L1-L2到L5-S1的水平)对它们的退化等级(Pfirrmann评分)进行分组,并使用3T MRI扫描仪在轴向和矢状面进行分析。使用维纳滤镜对轴向T1ρ加权图像进行后处理。将彩色图上跟踪的感兴趣区域(ROI)的中位轴向T1ρ值与每个光盘矢状面中相应位置的ROI进行比较。结果还比较了维纳后滤过的NP中轴T1ρ值与相应的矢状中值之间的统计学差异(P≥0.05)。较高的轴向T1ρ和生化测量的GAG含量对应于IVD的较低的Pfirrmann分级。观察到T1ρ值与GAG含量之间有很强的相关性(r?=?0.85,P?=?0.0002)。结论轴向T1ρ方法已针对矢状T1ρ进行了验证,从而提供了IVD的增强空间表示,并有助于局灶性变性的定位在IVD中。 T1ρ值可以更好地评估变性椎间盘疾病的粒度,因为它与蛋白聚糖浓度相关。因此,维纳滤波是从T1ρ加权轴向MR图像中去除噪声的有效工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号