Since its discovery, magnetic resonance imaging (MRI) has been one of the main methods of imaging in radiology. So far, there are not many national or international guidelines for MRI quality assurance compared to imaging methods that are using ionizing radiation. American College of Radiology (ACR) has an accreditation program that includes a standardized image quality measurement protocol and a phantom. Seven important assessments of MRI image quality are included with acceptance criteria. The aim of this study was to determine whether using the ACR MRI phantom would be a suitable quality assurance method for MRI systems in Estonia. In order to determine if the ACR MRI phantom would be a suitable quality assurance method for MRI systems in Estonia, six MRI scanners were tested using the ACR MRI accreditation program phantom and method. Information about the image quality was obtained and 33% of the MRI scanners passed all seven assessments. In conclusion, the ACR MRI phantom is a suitable test body for some of the MRI scanners in Estonia and should be considered to be used for regular quality testing. Due to the fact that in some cases the ACR MRI phantom did not fit into the head coil, using the ACR MRI phantom cannot be nationally required and other quality assurance phantoms should also be assessed. Adding signal-to-noise ratio assessment to seven assessment criteria, provided by ACR quality assurance manual, and developing an automated ACR quality assurance procedure would make quality assurance with ACR MRI phantom more beneficial.
机译:自从发现以来,磁共振成像(MRI)一直是放射学成像的主要方法之一。到目前为止,与使用电离辐射的成像方法相比,关于MRI质量保证的国家或国际准则并不多。美国放射学院(ACR)的认证计划包括标准化的图像质量测量协议和模型。接受标准包括对MRI图像质量的七个重要评估。这项研究的目的是确定使用ACR MRI体模是否将是爱沙尼亚MRI系统的合适质量保证方法。为了确定ACR MRI体模是否适合爱沙尼亚MRI系统的质量保证方法,使用ACR MRI认证程序体模和方法测试了六台MRI扫描仪。获得了有关图像质量的信息,并且33%的MRI扫描仪通过了所有七个评估。总之,ACR MRI体模是爱沙尼亚某些MRI扫描仪的合适测试体,应被视为用于常规质量测试。由于在某些情况下ACR MRI体模无法放入头部线圈中,因此无法在全国范围内要求使用ACR MRI体模,还应评估其他质量保证体模。将信噪比评估添加到ACR质量保证手册提供的七个评估标准中,并开发自动化的ACR质量保证程序,将使使用ACR MRI体模的质量保证更加有益。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号