首页> 外文期刊>Internet Journal of Orthopedic Surgery >A fracture through the neck of a Charnley Elite-Plus femoral component: a case report
【24h】

A fracture through the neck of a Charnley Elite-Plus femoral component: a case report

机译:Charnley Elite-Plus股骨颈骨折:一例

获取原文
           

摘要

Fracture of the femoral stem component following hip arthroplasty is an uncommon but recognised complication. The prevalence ranges between 0.23%, according to Charnley, and can be as high as 11% with other stem designs 1,2 . With the improvement of our understanding of biomechanics and the development of stronger metal alloys the prevalence of stem fractures has reduced.Fractures of the neck of femoral stems are even more rare with only a few cases reported 2 .We report a case of a fracture through the neck of a Charnley Elite-Plus femoral stem. To our knowledge this is the first reported case involving this stem. Introduction Fracture of the femoral stem component following hip arthroplasty is an uncommon but recognised complication. The prevalence ranges between 0.23%, according to Charnley, and can be as high as 11% with other stem designs1,2.With the improvement of our understanding of biomechanics and the development of stronger metal alloys the prevalence of stem fractures has reduced.Fractures of the neck of femoral stems are even more rare with only a few cases reported2.We report a case of a fracture through the neck of a Charnley Elite-Plus femoral stem. To our knowledge this is the first reported case involving this stem. Case presentation A 60-year old obese but active woman, weighing 95 kg and with a BMI of 34, underwent a cemented left total hip replacement for osteoarthritis in 1998. She did not have any significant past medical history. The implant inserted was a modular Elite plus stem, flanged 3, with a 28 mm metalic head and a 28mm inner diameter by 47mm outer diameter polyethylene cup.Her immediate post operative recovery was unremarkable. Post operative images showed a satisfactory position of the prosthesis.Ten years later she presented with an acute episode of severe left hip pain and inability to weight bear on that side. There was no history of trauma. Over the period of 10 years her weight had increased further to 115kg and her BMI to 41. She had also become more active as her mobility had improved. Radiographs of the left hip joint revealed a fracture through the neck of the femoral stem at the junction between the head and the neck (fig1).
机译:髋关节置换术后股骨干组件的骨折是一种罕见但公认的并发症。根据Charnley的说法,患病率在0.23%之间,对于其他茎杆设计1,2,患病率可高达11%。随着我们对生物力学的理解的提高和更强金属合金的发展,茎干骨折的患病率降低了。股骨干颈部骨折更为罕见,只有少数病例报告2。 Charnley Elite-Plus股骨柄的颈部。据我们所知,这是第一个涉及此茎的报道病例。引言髋关节置换术后股骨干成分骨折是一种罕见但公认的并发症。根据Charnley的说法,患病率在0.23%之间,在其他阀杆设计中可能高达11%1,2。随着我们对生物力学的了解和更强的金属合金的发展,阀杆骨折的患病率降低了。股骨颈的颈部更为罕见,仅报道了少数病例2。据我们所知,这是第一个涉及此茎的报道病例。病例介绍1998年,一名60岁,体重95公斤,体重指数(BMI)为34的肥胖但活跃的女性,接受了骨水泥置换左全髋置换术治疗骨关节炎。她没有任何重要的既往病史。插入的植入物是带法兰3的模块化Elite plus茎杆,带有28毫米金属头,28毫米内径乘47毫米外径的聚乙烯杯,术后立即恢复无明显异常。术后影像显示假体的位置令人满意。十年后,她出现了严重的左髋关节疼痛急性发作,并且无法承受体重。没有外伤史。在10年的时间里,她的体重进一步增加到115公斤,体重指数增加到41。随着行动能力的提高,她也变得更加活跃。左髋关节的X线照片显示,在股骨头与头部之间的连接处,股骨颈骨折(图1)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号