An antimony film electrode for anodic stripping voltammetric analysis in complex solution wasinvestigated, with lead and cadmium employed as test metal ions. Ascorbic acid or dopamine, whichexist in most mammals and their metabolites in relatively high concentrations, interfere with thedetermination of metal ions by electrochemical stripping analysis. The influence of ascorbic acid anddopamine on the stripping voltammetric response of antimony film electrodes was evaluated. Theadsorption of these biomolecules onto the electrode caused decreased and non-distinguishablestripping peaks. The interference of the biomolecules on antimony stripping electrodes can beovercome by Nafion pre-coating. In situ deposited antimony/Nafion-coated glassy carbon electrodesexhibited higher sensitivity for electrochemical stripping analysis of cadmium and lead with limit ofdetection approximately 0.015 g L-1 in the presence of ascorbic acid or dopamine. The effective anti- fouling capability to ascorbic acid or dopamine makes the in situ deposited antimony/Nafion-coatedelectrode very attractive for direct measurements of trace metals in complex media.
机译:研究了用于复杂溶液中阳极溶出伏安法分析的锑膜电极,其中铅和镉用作测试金属离子。大多数哺乳动物及其相对较高浓度的代谢产物中存在的抗坏血酸或多巴胺会通过电化学溶出分析干扰金属离子的测定。评估了抗坏血酸和多巴胺对锑膜电极溶出伏安法响应的影响。这些生物分子在电极上的吸附导致减少的峰和不可分辨的剥离峰。 Nafion预涂层可以克服生物分子对锑剥离电极的干扰。在抗坏血酸或多巴胺的存在下,原位沉积的锑/ Nafion涂层玻碳电极对镉和铅的电化学剥离分析具有更高的灵敏度,检测限约为0.015 g L-1。对抗坏血酸或多巴胺的有效防污能力使原位沉积的锑/ Nafion涂层电极对于直接测量复杂介质中的痕量金属非常有吸引力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号