首页> 外文期刊>International Journal of Electrochemical Science >Corrosion Behavior of Ti-6Al-7Nb Alloy in Biological Solution for Dentistry Applications
【24h】

Corrosion Behavior of Ti-6Al-7Nb Alloy in Biological Solution for Dentistry Applications

机译:牙科应用生物溶液中Ti-6Al-7Nb合金的腐蚀行为

获取原文
           

摘要

The corrosion behavior of titanium alloy without vanadium Ti-6Al-7Nb under simulatedbiological conditions was investigated and compared with that of titanium and Ti-6Al-4V alloy, whichemployed as biomaterials. The aim of the present study was to evaluate their corrosion performancethrough the analysis of open circuit potential (OCP) and corrosion resistance using electrochemicalimpedance spectroscopy (EIS) tests. A high corrosion resistance was obtained for Ti-6Al-7Nbcompared to that of titanium and TiAlV alloy, indicating a typical passive behavior for Ti-6Al- 7Nb alloy, which can be attributed to a highly stable film formed on Ti-6Al-7Nb alloy in Hanksolution. The corrosion resistance of the three electrodes was in the order of Ti > Ti-6Al-7Nb > Ti- 6Al-4V . Thus, Ti-6Al-7Nb can be used instead of Ti-6Al-4V to avoid the problems related withvanadium.
机译:研究了不含钒的Ti-6Al-7Nb钛合金在模拟生物学条件下的腐蚀行为,并将其与用作生物材料的钛和Ti-6Al-4V合金进行了比较。本研究的目的是通过使用电化学阻抗谱(EIS)测试分析开路电位(OCP)和耐腐蚀性来评估其腐蚀性能。与钛和TiAlV合金相比,Ti-6Al-7Nb具有较高的耐腐蚀性,这表明Ti-6Al-7Nb合金具有典型的钝化性能,这可以归因于在Ti-6Al-7Nb合金上形成的高度稳定的膜在Hanksolution中。三个电极的耐蚀性依次为Ti> Ti-6Al-7Nb> Ti-6Al-4V。因此,可以使用Ti-6Al-7Nb代替Ti-6Al-4V,以避免与钒有关的问题。