首页> 外文期刊>Indian journal of Anaesthesia >Disinfection of laryngoscopes: A survey of practice
【24h】

Disinfection of laryngoscopes: A survey of practice

机译:喉镜消毒:实践调查

获取原文
           

摘要

Background and Aims: The laryngoscope is a common piece of equipment used by anaesthesiologists. It has been identified as a potential source of cross infection. Although guidelines exist regarding appropriate disinfection practices, recent reviews suggest ineffectiveness of current methods of disinfection and poor compliance with the established protocols. We conducted a questionnaire-based survey to study the current disinfection practices being followed by a cross section of anaesthesiologists. Methods: A simple questionnaire containing 13 questions was distributed amongst anaesthesiologists in an anaesthesia conference. Data were analysed with percentage analysis. Results: Out of 250 delegates who attended the conference, 150 submitted the completed questionnaires. Residents constituted 41% and 46% were consultants. Eighteen (12%) used only tap water for cleaning and 132 (88%) used a chemical agent after rinsing with water. Out of 132, 76 (51%) used detergent/soap solution, 29 (19%) would wash and then soak in disinfectant or germicidal agents (glutaraldehyde, povidone iodine and chlorhexidine) and 18 (12%) would wipe the blade with an alcohol swab. With respect to disinfection of laryngoscope handles, 70% respondents said they used an alcohol swab, 18% did not use any method, 9% were not aware of the method being used, while 3% did not respond. Conclusion: Our results indicate wide variation in methods of decontamination of laryngoscopes. Awareness regarding laryngoscope as a potential source of infection was high. We need to standardise and implement guidelines on a national level and make available resources which will help to improve patient safety.
机译:背景与目的:喉镜是麻醉医师常用的设备。它已被确定为交叉感染的潜在来源。尽管存在有关适当的消毒方法的准则,但最近的评论表明,当前的消毒方法无效且对既定规程的依从性较差。我们进行了一项基于问卷的调查,以研究当前的消毒实践,随后各科麻醉师将进行调查。方法:在麻醉会议上向麻醉师分发了一个包含13个问题的简单问卷。用百分比分析法分析数据。结果:在参加会议的250位代表中,有150位提交了完整的问卷。居民占41%,顾问占46%。十八(12%)只使用自来水进行清洗,而132(88%)用水冲洗后使用化学试剂。在132种洗涤剂中,有76种(51%)用过的洗涤剂/肥皂溶液,其中29种(19%)将被洗涤,然后浸泡在消毒剂或杀菌剂(戊二醛,聚维酮碘和洗必泰)中,而18种(12%)将用酒精棉签。关于喉镜手柄的消毒,有70%的被调查者说他们使用了酒精拭子,18%的人没有使用任何方法,9%的人不知道所使用的方法,而3%的人没有反应。结论:我们的结果表明喉镜净化方法的差异很大。关于喉镜作为潜在感染源的认识很高。我们需要在全国范围内标准化和实施指南,并提供可用资源,以帮助改善患者安全。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号