摘要

The complicated structure of heat-supply pipe network leads to the issue that the leakage position is difficult to locate by a single sensor. We propose to exploit the merge information by multi-sensor to determine the leakage pipeline section. The mathematical model is first established according to the topology of the pipe network. Furthermore, We present the concept of leakage time difference vector group and assign the elementary probability according to the cosine of the intersection angle between the given time difference vector group and the real measured time difference vector group. Experimental results show that the proposed scheme realizes the diagnosis of the leakage pipeline section in the complicated heat-supply pipe network.
机译:供热管网结构复杂,导致单个传感器难以定位泄漏位置的问题。我们建议利用多传感器的合并信息来确定泄漏管道的部分。首先根据管网的拓扑建立数学模型。此外,我们提出了泄漏时间差矢量组的概念,并根据给定的时间差矢量组和实际测量的时间差矢量组之间的交角的余弦值分配基本概率。实验结果表明,该方案实现了复杂的供热管网泄漏管道段的诊断。