...
首页> 外文期刊>Indian journal of orthopaedics >Nonunion of greater trochanter following total hip arthroplasty: Treated by an articulated hook plate and bone grafting
【24h】

Nonunion of greater trochanter following total hip arthroplasty: Treated by an articulated hook plate and bone grafting

机译:全髋关节置换术后大转子的骨不连:通过关节钩板和植骨治疗

获取原文
           

摘要

Background: Trochanteric osteotomy still has an important role in hip arthroplasty in cases of (1) preexisting developmental hip dysplasia with superior subluxation, (2) revision arthroplasty, specifically with acetabular component revision in the face of well-fixed femoral component, and (3) recurrent dislocation without component loosening or malalignment, in treatment of complicated trochanteric fixation in osteoporotic bone and nonunions may be difficult. This study reports the clinical outcomes of trochanteric fixation following total hip arthroplasty (THA) utilizing a hook plate construct in a cohort of ten patients. Materials and Methods: The Arbeitsgemeinschaft für Osteosynthesefragen (AO) articulated hook plate was used in nine cases of established approach related nonunion following THA and in one case of osteopenic bone during primary THA. All ten patients returned for interviews and clinical examination. The average time for clinical followup was 35 months (range 5–48 months). The mean age of the study cohort was 65 years (range 56–74 years). Time to union and incidence of postoperative complications were assessed. Results: Union occurred in all ten cases at an average of 3.3 months postoperatively. One patient developed symptomatic trochanteric bursitis and required plate removal. Another patient developed a superficial infection which was successfully treated with local wound debridement and antibiotics. A third patient developed a symptomatic neuroma at the site of the iliac crest bone harvest and was successfully treated with excision of the neuroma. No catastrophic implant failures occurred. Conclusions: The articulated design of the plate allows for ease in application and functional construct stability. The articulated hook plate is an option for fixation of osteopenic bone fragments and established nonunions of the greater trochanter.
机译:背景:在以下情况下,转子粗隆截骨术在髋关节置换术中仍然起着重要作用:(1)先前存在过半脱位的发育性髋关节发育不良,(2)翻修置换术,特别是面对固定良好的股骨组件进行髋臼翻修,以及(3 )反复脱位而无组件松动或错位,在治疗骨质疏松性骨和复杂的转子粗隆内固定时可能会很困难。这项研究报告了在十名患者的队列中使用钩板构建物进行全髋关节置换术(THA)后股骨转子固定的临床结果。材料与方法:9例THA术后已建立入路相关的骨不连和1例初次THA期间骨质疏松的骨均使用ArbeitsgemeinschaftfürOsteosynthesefrafra(AO)铰接钩板。所有十名患者返回接受采访和临床检查。临床随访的平均时间为35个月(5至48个月)。研究队列的平均年龄为65岁(范围为56-74岁)。工会的时间和术后并发症的发生率进行了评估。结果:全部十例患者均发生联合,平均术后3.3个月。一名患者出现了症状性股骨转子滑囊炎,需要摘除钢板。另一例患者发生浅表感染,已成功用局部伤口清创术和抗生素治疗。第三名患者在harvest骨骨收获部位出现了症状性神经瘤,并成功切除了神经瘤。没有发生灾难性的植入失败。结论:板的铰接设计使得其易于使用和功能构造的稳定性。铰接的钩板是固定骨质疏松骨碎片和大转子的不愈合骨的一种选择。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号