首页> 外文期刊>Indian Journal of Critical Care Medicine >Is liquid heparin comparable to dry balanced heparin for blood gas sampling in intensive care unit?
【24h】

Is liquid heparin comparable to dry balanced heparin for blood gas sampling in intensive care unit?

机译:重症监护病房的血液气体采样中,液态肝素是否可与干平衡肝素媲美?

获取原文
           

摘要

Introduction: Blood gas (BG) analysis is required for management of critically ill patients in emergency and intensive care units. BG parameters can be affected by the type of heparin formulations used-liquid heparin (LH) or dry balanced heparin (DBH). This study was conducted to determine whether blood gas, electrolyte, and metabolite estimations performed by using DBH and LH are comparable. Materials and Methods: A prospective study was conducted at pediatric intensive care unit (PICU) of a tertiary care hospital. Paired venous samples were collected from 35 consecutive children in commercially prepared DBH syringes and custom-prepared LH syringes. Samples were immediately analyzed by blood gas analyzer and compared for pH, pCO 2 , pO 2 , HCO 3 - , Na + , K + , Cl - , and lactate. Paired comparisons were done and agreement was assessed by Bland-Altman difference plots. The 95% limits of absolute agreement (LOA) were compared with the specifications for total allowable error (TEa). Results: The P values were significant for all measured parameters, with the exception of pCO 2 and K +. Bland-Altman difference plots showed wide LOA for pCO 2 , pO 2 , HCO3 - , Na + , K + , and Cl - when compared against TEa. For pCO 2 , HCO3 - , Na + , K + , and Cl - , 40%, 23%, 77%, 34%, and 54% of samples were outside the TEa limits, respectively, with LH. Conclusion: Our study showed that there is poor agreement between LH and DBH for the BG parameters pCO2, pO2, HCO3 - , K + , Na + , and Cl - and, thus, are not comparable. But for pH and lactate, LH and DBH can be used interchangeably.
机译:简介:急诊和重症监护病房的重症患者管理需要进行血气(BG)分析。 BG参数可能会受到所用肝素制剂类型的影响-液体肝素(LH)或干平衡肝素(DBH)。进行这项研究是为了确定使用DBH和LH进行的血气,电解质和代谢物评估是否具有可比性。材料和方法:前瞻性研究是在三级护理医院的儿科重症监护室(PICU)进行的。使用商业准备的DBH注射器和定制制备的LH注射器从35个连续的儿童中收集配对的静脉样本。立即通过血气分析仪分析样品并比较其pH,pCO 2 ,pO 2 ,HCO 3 - ,Na + ,K + ,Cl -和乳酸。进行配对比较,并通过Bland-Altman差异图评估一致性。将95%的绝对一致性限制(LOA)与总允许误差(TEa)的规范进行了比较。结果:除pCO 2 和K +外,所有测量参数的P值均显着。 Bland-Altman差异图显示pCO 2 ,pO 2 ,HCO3 -,Na + ,K的LOA较宽与TEa比较时, + 和Cl -。对于pCO 2 ,HCO3 -,Na + ,K + 和Cl -,分别有40%,23%,77%,34%和54%的样本超出LHA的TEa限制。结论:我们的研究表明,对于BG参数pCO2,pO 2, HCO3 -,K + ,LH和DBH之间的一致性差。 Na + 和Cl -,因此不可比。但是对于pH和乳酸,LH和DBH可以互换使用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号